Study of Load Adjustment Strategy for Nuclear Power Units Focusing on Rankine Cycle: Flexibility–Environment–Economy

Author:

Zhu Lingkai1,Zheng Wei1,Wang Wenxing2,Zhong Ziwei1,Guo Junshan1,Song Jiwei2

Affiliation:

1. State Grid Shandong Electric Power Research Institute, Jinan 250003, China

2. Institute of Thermal Science and Technology, Shandong University, Jinan 250061, China

Abstract

The demand for the power grid system’s capacity to undergo peak-shaving is increasing as the proportion of renewable energy rises. In China, nuclear power units usually only provide a base load operation in the view of safety and economic considerations, but they do not provide load adjustment services, which undoubtedly increases the pressure of grid load adjustment. In this paper, a novel flexibility load adjustment strategy of the CHP nuclear unit is studied, which is achieved by introducing the thermal storage tank (TST) into the Rankine cycle without changing the output of the nuclear reactor. The AP1000 pressurized water reactor nuclear power unit for combined heat and power is taken as an example, and the thermodynamic model is established through the water vapor equation. Furthermore, the reference system is simulated for the goal of minimizing the imbalance between power supply and demand, and the flexibility–environment–economy benefits are evaluated. The results show that the heat storage/release of the TST may achieve power output flexible adjustment of the nuclear unit, and the power imbalance of the reference energy system is reduced from 1107.99 MWh to 457.24 MWh, a reduction of 58.73%. The introduction of a 600 MWh TST can enable the reference unit to contribute 335 MWh of peak electricity within the reference day. From the perspective of replacing the power generation output increment of coal-fired power units with equal amounts, it can achieve a reduction of 106.09 tons of coal consumption in the case day, which means that 277.73 tons of CO2 emissions can be reduced. The profit of the reference unit can be improved by CHY 70,125 via participating in load adjustment in the case day if following the time-of-use electricity price.

Funder

Science and Technology Project of State Grid Shandong Electric Power Research Institute

Publisher

MDPI AG

Reference15 articles.

1. (2024, February 17). The Fourteenth Five-Year Plan for Energy Development of Shandong Province, Available online: http://fgw.shandong.gov.cn/art/2021/8/19/art_250630_10361220.html.

2. China’s nuclear power development after Fukushima Nuclear Power Station accident;Yezhen;Proc. Chin. Soc. Electr. Eng.,2012

3. Robust nonlinear model predictive control for nuclear power plants in load following operations with bounded xenon oscillations;Eliasi;Nucl. Eng. Des.,2011

4. Intermittency and the Value of Renewable Energy;Gowrisankaran;J. Politi-Econ.,2016

5. Evaluating the limits of solar photovoltaics (PV) in electric power systems utilizing energy storage and other enabling technologies;Denholm;Energy Policy,2007

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3