Energy Management of Hybrid DC Microgrid with Different Levels of DC Bus Voltage for Various Load Types

Author:

Elmorshedy Mahmoud F.12ORCID,Subramaniam Umashankar1ORCID,Mohamed Ali Jagabar Sathik13ORCID,Almakhles Dhafer1ORCID

Affiliation:

1. Renewable Energy Lab., College of Engineering, Prince Sultan University, Riyadh 11586, Saudi Arabia

2. Electrical Power and Machines Engineering Department, Faculty of Engineering, Tanta University, Tanta 31733, Egypt

3. Department of Electrical and Electronics Engineering, SRM Institute of Science and Technology, Kattankulathur Campus, Chennai 603203, India

Abstract

This article suggests a hybrid DC microgrid (HDCMG) with different levels of DC bus voltages to use for various types of loads. The available sources in the HDCMG are wind generating systems (WGSs), photovoltaic (PV) systems, battery banks, and the AC grid for emergencies. The various levels of the DC bus voltages are 760 V, 380 V, and 48 V for different application uses such as electric vehicles and home applications. In addition, the controller plays an important role in the proposed system to achieve the desired DC bus voltage levels and extract the maximum power point (MPP) from the WGS and PV systems. In order to check the power continuity for the critical loads and improve the overall system performance, a suggested energy management strategy (SEMS) is developed. The SEMS is based on the optimum generated power and the state-of-charge (SOC) of the battery banks. Further, the SEMS is developed as a way to prevent battery storage from overcharging and deep discharging. The mathematical relations of the proposed HDCMG and MPP tracking are described. The bidirectional 3-Φ inverter connects the 760 V bus voltage to the AC grid for regulating this DC bus by absorbing the excess power or supplying the required power during the shortage in the generation and the low SOC of the battery storage. Buck converters with controlled duty cycles rather than constant duty cycles are used to obtain 380 V and 48 V from 760 V to achieve better dynamic responses. The overall HDCMG is evaluated using the MATLAB/Simulink package under different working cases to verify the capability of the control system and the PEMS. The obtained results are discussed and show the good performance and the capability of the overall system under the different scenarios, including (i) a comparison between variable duty and constant duty; (ii) high/low generated power and the SOC of the battery in the acceptable region; (iii) high/low generated power and the SOC of the battery in the critical region; and (iv) high/low generated power and the SOC of the battery in the overcharging region.

Funder

Prince Sultan University

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3