Procedure-Related Differences and Clinical Outcomes in Patients Treated with Percutaneous Coronary Intervention Assisted by Optical Coherence Tomography between New and Earlier Generation Software (Ultreon™ 1.0 Software vs. AptiVue™ Software)

Author:

Januszek RafałORCID,Siłka WojciechORCID,Sabatowski Karol,Malinowski Krzysztof PiotrORCID,Heba Grzegorz,Surowiec Sławomir,Chyrchel Michał,Rzeszutko Łukasz,Bryniarski Leszek,Surdacki AndrzejORCID,Bartuś Krzysztof,Bartuś Stanisław

Abstract

(1) Introduction: Optical coherence tomography (OCT) intravascular imaging facilitates percutaneous coronary intervention (PCI). Software for OCT is being constantly improved, including the latest version Ultreon™ 1.0 Software (U) (Abbott Vascular, Santa Clara, CA, USA). In the current analysis, we aim to compare processing results, procedural indices as well as clinical outcomes in patients treated via PCI. This was conducted using earlier generation OCT imaging software versions (non-U) and the newest available one on the market (U). (2) Methods: The study comprised 95 subsequent and not selected patients (55 processed with U and 40 non-U). The non-U processings were transferred for evaluation by U software, while the comparison of OCT parameters, selected clinical and procedural indices was performed between groups. We further assessed clinical outcomes during the follow-up period, i.e., major adverse cardiovascular events (MACE) and predictors of stent expansion. (3) Results: We did not detect any differences in general features between either of the assessed groups at baseline. Non-U software was more often used for bare-metal stenting (p = 0.004), while PCIs in the U group demanded a greater number of stents (p = 0.03). The distal reference of external elastic lamina (EEL) diameter was greater in the non-U group (p = 0.02) with no concurrent differences in minimal (p = 0.27) and maximal (p = 0.31) stent diameter. It was also observed that MACE was more frequently observed in the non-U group (p = 0.01). Neither univariable (estimate: 0.407, 95%CI: (−3.182) − 3.998, p = 0.82) nor multivariable (estimate: 2.29, 95%CI: (−4.207) − 8.788, p = 0.5) analyses demonstrated a relationship between the type of software and stent expansion. (4) Conclusions: Improvement in the software for image acquisition and processing of OCT is not related to stent expansion. The EEL diameter is preferably used to select the distal stent diameter in newer software.

Publisher

MDPI AG

Subject

Pharmacology (medical),General Pharmacology, Toxicology and Pharmaceutics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3