The Design and Processor-In-The-Loop Implementation of a Super-Twisting Control Algorithm Based on a Luenberger Observer for a Seamless Transition between Grid-Connected and Stand-Alone Modes in Microgrids

Author:

Aillane Ali1ORCID,Dahech Karim1,Chrifi-Alaoui Larbi2ORCID,Chouder Aissa3,Damak Tarak1,Hadjkaddour Abdelhak4ORCID,Bussy Pascal2

Affiliation:

1. Laboratory of Sciences and Techniques of Automatic Control and Computer Engineering (Lab-STA), National School of Engineering of Sfax (ENIS), University of Sfax, Sfax 3038, Tunisia

2. Laboratory of Innovative Technology (LTI, UR 3899), University of Picardie Jules Verne, 80000 Amiens, France

3. Electrical Engineering Laboratory, University Mohamed Boudiaf of M’sila, M’sila 28000, Algeria

4. Laboratory of Electrical Engineering and Automation, University Yahia Fares Medea, Medea 26000, Algeria

Abstract

The abrupt transfer from grid-connected (GC) to stand-alone (SA) operation modes is one of the major issues that may threaten the stability of a distributed generation (DG) system. Furthermore, if the islanding mode happens, it is vital to take into consideration the load voltages or load current waveforms as soon as feasible. This paper develops an advanced control technique based on a super-twisting sliding mode controller (ST-SMC) for a three-phase inverter operating in both the GC and SA modes. This control scheme is proposed to ensure a smooth transition from the GC to SA mode and enhance the load voltage waveforms under the islanding mode. In addition, to minimize the operational costs of the system and the complexity of the studied model, a digital Luenberger observer (DLO) with a proper design is adopted for estimating the inverter-side current. The control scheme of the whole system switches between a current control mode during the GC mode and a voltage control mode during the SA mode. The super-twisting control algorithm is applied to the outer voltage control loop involved in the cascaded voltage/current control scheme in the SA mode. Simulation tests of a three-phase inverter are performed for the purpose of assessing the suggested control performance by using the PowerSim (PSIM) software and comparing it with a classical PI controller. Furthermore, a processor-in-the-loop (PIL) implementation in a DSP board TMS32F28335 while debugging is conducted using code composer studio 6.2.0. The obtained results show efficient control properties, such as a smooth transition among the microgrid (MG) operating modes, as well as effectiveness and robustness during both the GC and SA operation modes.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3