Abstract
The conversion system is a major contributor to failure rates. These faults lead to time and cost consuming. Fault diagnosis capabilities pay as a solver to achieve a steady system. This paper presents a full analysis of permanent magnet synchronous generator wind system (PMSGWS) and proposes a special RMS voltage-based fault diagnosis method. The full analysis presents a comprehensive knowledge of faulty behaviors especially under arm current flowing or cutting off. Due to enough knowledge of faulty behaviors, the implementation of the detection method without threshold setting is contributed by the special RMS voltage. Its sample period is set longer than the time of the maximum pulse width ratio (MPR) and shorter than the fault show time of lower tube voltage. Due to this, the detection speed and robustness are achieved. By these simple settings for the fault diagnosis method, the faulty switch is detected in less than 1/4 of the period. Simulation and experimental results confirm the validity and feasibility of the new proposed fault detection method.