Abstract

Nowadays ultrasound-based non-invasive techniques for the evaluation of tissue elasticity are becoming increasingly popular. A key determinant for the adequate treatment of focal liver lesions is on establishment of accurate diagnosis. Contemporary imaging modalities, particularly ultrasonographic, are widely accepted for assessing the elasticity of focal liver lesions but the investigation of their accuracy and differentiation potential is still ongoing. Aim: To compare the values of point shear wave elastography (pSWE) and two-dimensional shear wave elastography (2D-SWE) for liver metastases from colorectal cancer. Materials and Methods: A total of 31 adult patients with liver metastases from colorectal cancer (CRC) were included from the Department of Gastroenterology of University Hospital Kaspela, Plovdiv, Bulgaria, in the period June 2022 to November 2022. The men/women ratio of the participants was respectively 11 women and 20 men. For all of them point shear wave elastography (pSWE) and two-dimensional shear wave elastography (2D-SWE) were performed to evaluate the stiffness of liver metastases, by measuring the shear wave velocity (SWV) in a region of interest (ROI). Prior histological confirmation of colorectal cancer through diagnostic lower endoscopy was a prerequisite for inclusion in the study. Contrast-enhanced computer tomography (CECT) was used as a reference imaging modality to confirm the presence of lesions in the liver. All the images were evaluated by a radiologist with long-standing experience in liver imaging. Results: For point shear wave elastography (pSWE), the lower limit was found to be 1.80 m/s (90% CI: 1.39 to 2.32) and the upper limit was 4.21 m/s (90% CI: 3.69 to 4.60). For two-dimensional shear wave elastography (2D-SWE), the lower limit was determined to be 1.87 m/s (90% CI: 1.54 to 2.25) and the upper limit was 3.65 m/s (90% CI: 3.26 to 3.97). Conclusions: Point shear wave elastography (pSWE) and two-dimensional shear wave elastography (2D-SWE) could bring additional information about the stiffness of liver metastases from colorectal cancer but they are not to be considered a method to substitute biopsy of colorectal cancer during lower endoscopy.

Publisher

MDPI AG

Subject

Gastroenterology,Hepatology

Reference31 articles.

1. New technologies in clinical ultrasound;Kamaya;Semin. Roentgenol.,2013

2. Sherlock, S. (1989). Diseases of the Liver and Biliary System: Needle Biopsy of the Liver, Blackwell Scientific Publications. [8th ed.].

3. Global patterns and trends in colorectal cancer incidence and mortality;Arnold;Gut,2017

4. Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries;Bray;CA Cancer J. Clin.,2018

5. Colorectal cancer: Prevention and early diagnosis;Bhat;Medicine,2015

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3