Usefulness of an Additional Filter Created Using 3D Printing for Whole-Body X-ray Imaging with a Long-Length Detector

Author:

Seo HyunsooORCID,Kim Wooyoung,Han BongjuORCID,Jang HuiminORCID,Yoon Myeong SeongORCID,Lee Youngjin

Abstract

We recently developed a long-length detector that combines three detectors and successfully acquires whole-body X-ray images. Although the developed detector system can efficiently acquire whole-body images in a short time, it may show problems with diagnostic performance in some areas owing to the use of high-energy X-rays during whole-spine and long-length examinations. In particular, during examinations of relatively thin bones, such as ankles, with a long-length detector, the image quality deteriorates because of an increase in X-ray transmission. An additional filter is primarily used to address this limitation, but this approach imposes a higher load on the X-ray tube to compensate for reductions in the radiation dose and the problem of high manufacturing costs. Thus, in this study, a newly designed additional filter was fabricated using 3D printing technology to improve the applicability of the long-length detector. Whole-spine anterior–posterior (AP), lateral, and long-leg AP X-ray examinations were performed using 3D-printed additional filters composed of 14 mm thick aluminum (Al) or 14 mm thick Al + 1 mm thick copper (Cu) composite material. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and radiation dose for the acquired X-ray images were evaluated to demonstrate the usefulness of the filters. Under all X-ray inspection conditions, the most effective data were obtained when the composite additional filter based on a 14 mm thick Al + 1 mm thick Cu material was used. We confirmed that an SNR improvement of up to 46%, CNR improvement of 37%, and radiation dose reduction of 90% could be achieved in the X-ray images obtained using the composite additional filter in comparison to the images obtained with no filter. The results proved that the additional filter made with a 3D printer was effective in improving image quality and reducing the radiation dose for X-ray images obtained using a long-length detector.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3