Improved On-Orbit MTF Measurement Method Based on Point Source Arrays

Author:

Li Litao1ORCID,Cao Jiayang1,Wei Shaodong2,Jiang Yonghua3ORCID,Shen Xin2ORCID

Affiliation:

1. College of Urban and Environmental Sciences, Hubei Normal University, Huangshi 435002, China

2. State Key Laboratory of Information Engineering in Surveying, Mapping, and Remote Sensing, Wuhan University, Wuhan 430079, China

3. School of Remote Sensing and Information Engineering, Wuhan University, Wuhan 430079, China

Abstract

The modulation transfer function (MTF) is a key characteristic used to assess the performance of optical remote sensing satellite sensors. MTF detection can directly measure a sensor’s two-dimensional (2D) point spread function (PSF); therefore, it has been applied to various high-resolution remote sensing satellites (e.g., Pleiades) using point sources. However, current point source methods mainly use 2D Gaussian functions to fit the discrete digital number (DN) of the point source on the image to extract the center of the point source and fit the PSF after encrypting multiple point sources; thus, noise robustness is poor and measurement accuracy varies widely. In this study, we developed a noise-resistant on-orbit MTF detection method based on the object space constraint among point source arrays. Utilizing object space constraint relationships among points in a point source array, a homography transformation model was established, enabling accurate extraction of sub-pixel coordinates for each point source response. Subsequently, aligning the luminosity distribution of all point sources concerning a reference point source, the encrypted PSF was obtained and then fitted to obtain the MTF. To validate the method, Gaofen-2 (GF-2) satellite images were used to conduct an in-orbit imaging experiment on the point source array of the Chinese Zhongwei remote sensing satellite calibration site. Compared with the Gaussian model methods, the proposed method yielded more accurate peak positions for each point source. Standard deviations of peak position constant ratios in along- and cross-track directions improved by 2.8 and 4.8 times, respectively. The root-mean-square error (RMSE) of the collinearity test results increased by 92%, and the noise resistance of the MTF curve improved by two times. Dynamic MTF values at the Nyquist frequency for the GF-2 panchromatic band in along- and cross-track directions were 0.0476 and 0.0705, respectively, and MTF values in different directions were well distinguished.

Funder

Hubei Provincial Natural Science Foundation of China

National Natural Science Foundation of China

Publisher

MDPI AG

Subject

General Earth and Planetary Sciences

Reference34 articles.

1. Kabir, S., Leigh, L., and Helder, D. (2020). Vicarious methodologies to assess and improve the quality of the optical remote sensing images: A critical review. Remote Sens., 12.

2. A procedure for high resolution satellite imagery quality assessment;Crespi;Sensors,2009

3. Helde, D., Choi, J., and Anderson, C. (2007). On-Orbit Modulation Transfer Function (MTF) Measurements for IKONOS and QuickBird, South Dakota State.

4. Kohm, K. (2004, January 12–23). Modulation Transfer Function Measurement Method and Results for the Orbview-3 High Resolution Imaging Satellite. Proceedings of the ISPRS, Istanbul, Turkey. Available online: https://www.isprs.org/proceedings/XXXV/congress/comm1/papers/2.pdf.

5. Choi, T. (2002). IKONOS Satellite on Orbit Modulation Transfer Function (MTF) Measurement Using Edge and Pulse Method, South Dakota State University.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3