Accuracy of the Provisional Prosthesis Scanning Techniqueversus a Conventional Impression Technique on Completely Edentulous Arches

Author:

Lee ChunuiORCID,Dusmukhamedov Shavkat,Fang Yi-Qin,Jeong Seung-Mi,Choi Byung-HoORCID

Abstract

Purpose: In this study, we aimed to compare the marginal fit of fixed dental restorations fabricated with the provisional prosthesis scanning technique versus a conventional impression technique and to determine the effect of both variables on the accuracy outcome. Materials and Methods: Twelve identical polyurethane edentulous maxillary models were equally divided into two groups: control (conventional impression group) and test (provisional prosthesis scanning group). After obtaining the impression using the above-mentioned methods and further preparing the final prosthesis, the passivity of the metal framework prosthesis was checked using a single screw test, i.e., only one screw was fixed on the terminal right abutment, and all others were empty. The marginal fit of the final prosthetic frameworks screwed onto the implants on the terminal left abutment was measured at the terminal right sight by periapical radiographs obtained immediately after metal framework placements in both groups. The medians derived from the two groups were compared using the Mann–Whitney test. In all tests, a p-value < 0.05 indicated statistical significance. Results: In the provisional prosthesis scanning group, the median marginal fit discrepancy was 170 µm (range 120–190). In the conventional impression group, the median marginal fit discrepancy was 1080 µm (range 1040–1100). There was a significant difference in the implant-framework marginal gap fit discrepancy between these two groups. Conclusion: Prostheses fabricated with the provisional prosthesis scanning technique are significantly more accurate than those fabricated with conventional impression techniques.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Digital Denture Fabrication: A Technical Note;Applied Sciences;2021-08-31

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3