Visualization of the Postoperative Position of the Hydrus® Microstent Using Automatic 360° Gonioscopy

Author:

Zimmermann Julian Alexander1,Kleemann Sarah1,Storp Jens Julian1ORCID,Weich Cedric1ORCID,Merté Ralph-Laurent1,Eter Nicole1,Brücher Viktoria Constanze1ORCID

Affiliation:

1. Department of Ophthalmology, University of Muenster Medical Center, 48149 Muenster, Germany

Abstract

Introduction: Glaucoma, one leading cause of irreversible vision loss worldwide, is primarily caused by elevated intraocular pressure (IOP). Recently, minimally invasive glaucoma surgeries (MIGSs) have become popular due to their shorter surgical times, tissue-sparing nature, and faster recovery. One such MIGS, the Hydrus® nickel–titanium alloy Microstent, helps lower IOP by improving aqueous humor outflow. The NIDEK GS-1 automated 360° gonioscope provides advanced imaging of the chamber angle for evaluation and documentation. The aim of this study was to test automated 360° gonioscopy for the detection of postoperative positional variations after Hydrus® Microstent implantation. This study is the largest to date to evaluate post-op positioning of the Hydrus® Microstent using the NIDEK GS-1. Materials and Methods: This study analyzed postoperative outcomes and stent location in eyes diagnosed with mild to moderate glaucoma that underwent Hydrus® Microstent implantation with or without phacoemulsification. Patients with prior IOP-lowering surgery or vitrectomy were excluded. Analyses of the postoperative Hydrus® Microstent position were based on the evaluation of automated 360° gonioscopy images. Results: Twenty-three eyes were included in the study, and all showed a reduction in IOP and a decrease in antiglaucomatous drop use postoperatively. Postoperative gonoscopic images showed variations in implant position. In all cases, the proximal inlet was clearly visible in the anterior chamber. The degree of protrusion into the anterior chamber was variable. The distal tip of the stent was visible behind the trabecular meshwork in Schlemm’s canal in five cases, in the anterior chamber in one case, and not visible in seven cases. In no case did postoperative alterations in the position of the implant lead to explantation. Conclusions: This study demonstrated that the Hydrus® Microstent can effectively lower IOP even in the presence of postoperative positional variations. Automated 360° gonioscopy was found to be a useful tool to verify and document the postoperative position of the implant. Positional changes did not require device explantation in any of the cases evaluated.

Funder

Open Access Publication Fund of the University of Muenster

Publisher

MDPI AG

Reference24 articles.

1. The Pathophysiology and Treatment of Glaucoma: A Review;Weinreb;JAMA,2014

2. Glaucoma;Jonas;Lancet,2017

3. Laser in Glaucoma and Ocular Hypertension (LiGHT) Trial: Six-Year Results of Primary Selective Laser Trabeculoplasty versus Eye Drops for the Treatment of Glaucoma and Ocular Hypertension;Gazzard;Ophthalmology,2023

4. Aktuelle Glaukomchirurgie;Hoffmann;Ophthalmologe,2021

5. IVANTIS (2024, August 02). Hydrus® Microstent Instructions for Use, Available online: https://www.accessdata.fda.gov/cdrh_docs/pdf17/P170034D.pdf.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3