BD Vacutainer™ Urine Culture & Sensitivity Preservative PLUS Plastic Tubes Minimize the Harmful Impact of Stressors Dependent on Temperature and Time Storage in Uropathogenic Bacteria

Author:

Treviño Samuel1,Ramírez-Flores Eduardo2,Cortezano-Esteban Steffany2,Hernández-Fragoso Hugo1,Brambila Eduardo3

Affiliation:

1. Laboratory of Metabolomic and Chronic Degenerative Diseases, Physiology Institute, Meritorious Autonomous University of Puebla, Prol. de la 14 Sur 6301, Ciudad Universitaria, Puebla C.P. 72560, Mexico

2. Center for Care and Research in Health Services, Urinalysis and Microbiology Area, Rio Nexapa 6153, Col. San Manuel, Puebla C.P. 72560, Mexico

3. Laboratory of Chemical-Clinical Investigations, Department of Clinical Chemistry, Chemistry Department, Meritorious Autonomous University of Puebla, 14 Sur. FCQ1, Ciudad Universitaria, Puebla C.P. 72560, Mexico

Abstract

Background: Urinary tract infection is a worldwide health problem. According to the Clinical Laboratory Improvement Amendments and the European Urinalysis Guideline, urine samples should be tested within 2 h of collection. Thus, using chemical preservatives that guarantee the pre-analytical conditions is a practical tool. However, the effects of temperature and storage time as uropathogenic bacteria stressors are unclear. Methods: Gram-negative and -positive ATTC strains, E. coli, P. mirabilis, E. faecalis, and S. aureus, were used in this study. Strains in liquid media were stored at 4, 25, and 37 °C for 0, 2, 12, 24, and 48 h in tubes with and without preservatives. Then, reactive oxygen species (ROS) levels, viable but non-culturable bacteria (VBNC), and bacteria growth were analyzed. Results: A high ROS level was associated with the presence of VBNC and dead bacteria with low CFU counts, but a low ROS level increased the CFU number, depending on temperature and storage time in tubes without preservatives (boric acid, sodium borate, and formate). The BD Vacutainer™ Urine Culture & Sensitivity Preservative PLUS Plastic Tubes (C&S-PP) prevent this ROS increase, maintaining the CFU number for longer. Conclusions: C&S-PP tubes minimize the stressor effects (temperature and time storage) on uropathogenic bacteria when stored, improving the pre-analytical conditions of cultures realized by the clinical laboratory.