Myocardial Fibrosis Quantification Methods by Cardiovascular Magnetic Resonance Imaging in Patients with Fabry Disease

Author:

Sokolska Justyna M.12,Károlyi Mihály3,Hiestand Dana R.2,Gastl Mareike4,Weber Lucas3ORCID,Sokolski Mateusz1,Kosmala Wojciech1ORCID,Alkadhi Hatem3ORCID,Gruner Christiane2,Manka Robert23ORCID

Affiliation:

1. Institute of Heart Diseases, Faculty of Medicine, Wroclaw Medical University, 50-556 Wroclaw, Poland

2. University Heart Center, Department of Cardiology, University Hospital Zurich, 8091 Zurich, Switzerland

3. Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland

4. Department of Cardiology, Pulmonology and Vascular Medicine, Heinrich Heine University Düsseldorf, 40225 Düsseldorf, Germany

Abstract

Background/Objectives: The presence of late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) in patients with Fabry disease (FD) is a predictor of adverse cardiac events. The aim of this study was to establish the most reliable and reproducible technique for quantifying LGE in patients with FD. Methods: Twenty FD patients with LGE who underwent CMR on the same scanner and LGE sequence were included. LGE quantifications were done using gray-scale thresholds of 2, 3, 4, 5 and 6 standard deviations (SD) above the mean signal intensity of the remote myocardium, the full width at half maximum method (FWHM), visual assessment with threshold (VAT) and the fully manual method (MM). Results: The mean amount of fibrosis varied between quantification techniques from 36 ± 19 at 2SD to 2 ± 2 g using the FWHM (p < 0.0001). Intraobserver reliability was excellent for most methods, except for the FWHM which was good (ICC 0.84; all p < 0.05). Interobserver reliability was excellent for VAT (ICC 0.94) and good for other techniques (all p < 0.05). Intraobserver reproducibility showed the lowest coefficient of variation (CV, 6%) at 5SD and at 2SD and VAT (35% and 38%) for interobserver reproducibility. The FWHM revealed the highest CV (63% and 94%) for both intra- and interobserver reproducibility. Conclusions: The available methods for LGE quantification demonstrate good to excellent intra- and interobserver reproducibility in patients with FD. The most reliable and reproducible techniques were VAT and 5SD, whereas the FWHM was the least reliable in the setting of our study. The total amount of LGE varies strongly with the quantification technique used.

Publisher

MDPI AG

Reference32 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3