Surface Microbial Contamination and Air Quality before and after Regular Cleaning Procedures

Author:

Mohammed Mohammed O. A.12ORCID

Affiliation:

1. Faculty of Public and Environmental Health, University of Khartoum, Khartoum 205, Sudan

2. Department of Public Health, College of Health Sciences, Saudi Electronic University, Riyadh 11673, Saudi Arabia

Abstract

Studies on indoor air quality (IAQ) have linked exposure to microorganisms in indoor air to a variety of illnesses. The association between indoor air quality, surface contamination, and IAQ under heterogeneous cleaning procedures are all crucial factors that were investigated in this study. The ATP bioluminescence test demonstrated a significant correlation (r = 0.89; p 0.05) with bacterial count obtained from swab specimens and a moderate correlation (r = 0.57; p 0.001) with viable settling bacterial count. For the entire sample (pre- and post-cleaning), the ATP values were heterogeneous, averaging 230 RLU/100 cm2, 140 RLU/100 cm2, 120 RLU/100 cm2, 135 RLU/100 cm2, 99 RLU/100 cm2, and 80 RLU/100 cm2, in offices, classrooms, toilet doorknobs, reception desks, main lobbies, and exit doorknobs, respectively. An insignificant association between indoor and outdoor PM2.5 (r = 0.21; p 0.05), an I/O ratio of PM2.5 with an average value of 1.2, and an I/O ratio of CO2 exceeding 1 suggest a minor impact of outdoor air. After cleaning, the bacterial and fungal counts on indoor surfaces showed significant reduction, suggesting that the cleaning procedures were effective. The concentrations of VOC but not HCHO in indoor air were significantly affected by cleaning, but not by temperature or relative humidity (RH). We propose ATP bioluminescence as a surrogate for detecting bacterial contamination rather than fungal contamination, which requires additional validation. We suggest that the results of active microbial sampling (in CFU/m3) and settling plates (in CFU/m2/h) be interpreted independently to avoid confusion.

Funder

Deanship of Scientific Research at Saudi Electronic University

Publisher

MDPI AG

Subject

Atmospheric Science,Environmental Science (miscellaneous)

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3