Abstract
This study systematically investigated the feasibility of the microbubble ozonation process to degrade the 17α-ethinylestradiol, ibuprofen, and atenolol through the comparison with the millibubble ozonation process for elucidating the degradation behavior and mechanisms during the microbubble ozonation processes. The proportions of small microbubbles (diameter 1–25 μm) were increased with increasing the cavity pump frequency (40 Hz: 51.4%; 50 Hz: 57.5%; 60 Hz: 59.9%). The increased concentrations of O3 and OH radicals due to the higher specific area of O3 microbubbles compared to O3 millibubbles could facilitate their mass transfer at the gas–water interface. Furthermore, the elevated reactivity of O3 by increasing the temperature might improve the degradation of the pharmaceutical compounds, which was more pronounced for the microbubble ozonated waters than the millibubble ozonated waters. Although the degradation efficiency of the pharmaceutical compounds during the microbubble ozonation processes was significantly influenced by the existence of humic acids compared to the millibubble ozonation process, the increased solubilization rate of O3 and OH radicals by collapsing O3 microbubbles enhanced the degradation of the pharmaceutical compounds. Overall, these results clearly showed that the microbubble ozonation process could be an alternative option to conventional ozonation processes for the abatement of the pharmaceutical compounds.
Subject
Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous)
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献