Affiliation:
1. Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London SW7 2AZ, UK
2. Non-Destructive Evaluation Group, Department of Mechanical Engineering, Imperial College London, London SW7 2AZ, UK
Abstract
Aseptic loosening is the dominant failure mechanism in contemporary knee replacement surgery, but diagnostic techniques are poorly sensitive to the early stages of loosening and poorly specific in delineating aseptic cases from infections. Smart implants have been proposed as a solution, but incorporating components for sensing, powering, processing, and communication increases device cost, size, and risk; hence, minimising onboard instrumentation is desirable. In this study, two wireless, battery-free smart implants were developed that used passive biotelemetry to measure fixation at the implant–cement interface of the tibial components. The sensing system comprised of a piezoelectric transducer and coil, with the transducer affixed to the superior surface of the tibial trays of both partial (PKR) and total knee replacement (TKR) systems. Fixation was measured via pulse-echo responses elicited via a three-coil inductive link. The instrumented systems could detect loss of fixation when the implants were partially debonded (+7.1% PKA, +32.6% TKA, both p < 0.001) and fully debonded in situ (+6.3% PKA, +32.5% TKA, both p < 0.001). Measurements were robust to variations in positioning of the external reader, soft tissue, and the femoral component. With low cost and small form factor, the smart implant concept could be adopted for clinical use, particularly for generating an understanding of uncertain aseptic loosening mechanisms.
Funder
Engineering and Physical Sciences Research Council
Reference51 articles.
1. Knee replacement;Carr;Lancet,2012
2. How long does a knee replacement last? A systematic review and meta-analysis of case series and national registry reports with more than 15 years of follow-up;Evans;Lancet,2019
3. Adverse outcomes after total and unicompartmental knee replacement in 101,330 matched patients: A study of data from the National Joint Registry for England and Wales;Liddle;Lancet,2014
4. Ben-Shlomo, Y., Blom, A., Boulton, C., Brittain, R., Clark, E., Dawson-Bowling, S., Deere, K., Esler, C., Espinoza, O., and Goldberg, A. (2021). The National Joint Registry 18th Annual Report 2021, National Joint Registry.
5. Aseptic loosening, not only a question of wear: A review of different theories;Sundfeldt;Acta Orthop.,2006