Remote Monitoring System of Dynamic Compression Bracing to Correct Pectus Carinatum

Author:

Real António12ORCID,Morais Pedro12ORCID,Oliveira Bruno12345ORCID,Torres Helena R.12345,Vilaça João L.12ORCID

Affiliation:

1. 2Ai—School of Technology, IPCA, 4750-810 Barcelos, Portugal

2. LASI—Associate Laboratory of Intelligent Systems, 4800-058 Guimaraes, Portugal

3. Algoritmi Center, School of Engineering, University of Minho, 4800-058 Guimaraes, Portugal

4. Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, 4710-057 Braga, Portugal

5. ICVS/3B’s—PT Government Associate Laboratory, 4710-057 Braga/Guimaraes, Portugal

Abstract

Pectus carinatum (PC) is a chest deformity caused by disproportionate growth of the costal cartilages compared with the bony thoracic skeleton, pulling the sternum forwards and leading to its protrusion. Currently, the most common non-invasive treatment is external compressive bracing, by means of an orthosis. While this treatment is widely adopted, the correct magnitude of applied compressive forces remains unknown, leading to suboptimal results. Moreover, the current orthoses are not suitable to monitor the treatment. The purpose of this study is to design a force measuring system that could be directly embedded into an existing PC orthosis without relevant modifications in its construction. For that, inspired by the currently commercially available products where a solid silicone pad is used, three concepts for silicone-based sensors, two capacitive and one magnetic type, are presented and compared. Additionally, a concept of a full pipeline to capture and store the sensor data was researched. Compression tests were conducted on a calibration machine, with forces ranging from 0 N to 300 N. Local evaluation of sensors’ response in different regions was also performed. The three sensors were tested and then compared with the results of a solid silicon pad. One of the capacitive sensors presented an identical response to the solid silicon while the other two either presented poor repeatability or were too stiff, raising concerns for patient comfort. Overall, the proposed system demonstrated its potential to measure and monitor orthosis’s applied forces, corroborating its potential for clinical practice.

Funder

Northern Portugal Regional Operational Programme

Fundação para a Ciência e a Tecnologia

Programa Operacional Capital Humano

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference18 articles.

1. Finite element analysis of pectus carinatum surgical correction via a minimally invasive approach;Neves;Comput. Methods Biomech. Biomed. Engin,2015

2. Russo, E., Bertani, A., De Monte, L., and Raffaele, F. (2020). Plastic and Cosmetic Surgery of the Male Breast, Springer.

3. Pectus carinatum;Desmarais;Curr. Opin. Pediatr.,2013

4. Chest wall anomalies: Pectus excavatum and pectus carinatum;Goretsky;Adolesc. Med. Clin.,2004

5. Surgical correction of pectus carinatum: Lessons learned from 260 patients;Fonkalsrud;J. Pediatr. Surg.,2008

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3