Abstract

The three-section courtyard is the most representative traditional residence in the traditional villages in northeast Sichuan. As a unique cultural landscape, it carries the local historical style and cultural connotation. However, the high temperature weather in summer leads to a poor thermal environment in traditional residential buildings, which cannot meet the needs of building users for human thermal comfort, and the wall is the most critical factor affecting the indoor thermal environment. Therefore, to optimise the indoor thermal environment of traditional residential buildings, this study designed four groups of wall renovation schemes according to the original traditional residential buildings and modern technology, and simulated and verified the feasibility of the building renovation schemes by using Design Builder. Then, the four groups of wall renovation schemes were compared and tested based on the Design Builder. Comparative results of the thermal-performance evaluation index revealed that compared with Case 1 and Case 2, the building refrigeration energy consumption of Case 3 in the hottest week was the least, only 427.7 kW·h, which indicates that the external wall renovation scheme using aerated concrete blocks had the best thermal insulation and energy-saving effects. The cooling energy consumption of Case 4 in the hottest week was 422 kW·h, which was 4.3 kW·h less than that of Case 3, indicating that the wall renovation scheme with an air inter-layer had better thermal insulation and energy-saving effects. The refrigeration energy consumption of Case 7 in the hottest week was only 409.8 kW·h, which was 4.19% lower than Case 3 (without insulation material), indicating that the scheme of selecting central insulation and extruded polystyrene board (XPS) had better thermal insulation and energy-saving effects in practical projects. In summary, the above transformation scheme not only improves the indoor thermal environment of traditional residential buildings, but also provides guidance for architectural designers on green, energy-saving and sustainable design.

Publisher

MDPI AG

Reference22 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3