On the Use of Ultrasonic Flowmeters for Cooling Energy Metering and Sub-Metering in Direct Expansion Systems

Author:

Aprea Ciro1,Canale Laura2ORCID,Dell’Isola Marco2ORCID,Ficco Giorgio2ORCID,Frattolillo Andrea3ORCID,Maiorino Angelo1ORCID,Petruzziello Fabio1ORCID

Affiliation:

1. Department of Industrial Engineering, University of Salerno, Via Giovanni Paolo II 132, 84084 Fisciano, SA, Italy

2. Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Via G. Di Biasio 43, 03043 Cassino, FR, Italy

3. Department of Civil, Environmental and Architecture Engineering, University of Cagliari, Via Marengo 2, 09123 Cagliari, CA, Italy

Abstract

The Energy Efficiency Directive (EED, Directive 2012/27/EU) has made mandatory the installation of individual metering systems in the case of buildings with centralized heating/cooling and hot water sources (multi-apartment and multi-purpose buildings), provided it is economically and technically feasible. Individual metering of heating/cooling systems is mainly based on thermal energy meters (TEM), which are widely used for direct metering in heating applications. On the other hand, direct metering of energy consumption in cooling systems still represents a challenge, given the different types of cooling units and the lack of regulations from the technical and legal points of view. In this context, this paper briefly overviews the available centralized cooling systems and the possible solutions for metering and sub-metering, which depend on the specific application. Vapour Compression Refrigeration (VCR) systems are spreading worldwide for air conditioning applications. Particular attention has been paid to the direct metering of cooling energy and specifically to refrigerant flow rate measurement, which represents a critical issue because of the small-diameter pipes and the different thermodynamic properties of the fluid used. Thus, an experimental campaign has been developed and carried out in order to compare a clamp-on ultrasonic flowmeter with a more accurate Coriolis one in a direct expansion (DE) system. The experimental tests have been performed at two different temperature conditions, showing a relative error in the mass flow rate measurements within ±10%.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Reference45 articles.

1. IEA (2019). Global Energy & CO2 Status Report—The Latest Trends in Energy and Emissions in 2018, IEA.

2. IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings;Yan;Energy Build.,2017

3. European Commission (2002). Directive 2002/91/EC of the European Parliament and of the council of 16 December 2002 on the Energy Performance of Buildings. Off. J. Eur. Commun., 46, 65–71.

4. A review on optimized control systems for building energy and comfort management of smart sustainable buildings;Shaikh;Renew. Sustain. Energy Rev.,2014

5. IEA (2020). Is Cooling the Future of Heating?, IEA. Available online: https://www.iea.org/commentaries/is-cooling-the-future-of-heating.