Fine Calibration Method for Laser Altimeter Pointing and Ranging Based on Dense Control Points

Author:

Xu Chaopeng12,Mo Fan2,Wang Xiao3,Yang Xiaomeng12,Xie Junfeng2,Wen Zhen12

Affiliation:

1. College of Geodesy and Geomatics, Shandong University of Science and Technology, Qingdao 266590, China

2. Land Satellite Remote Sensing Application Center, Ministry of Natural Resources of China, Beijing 100048, China

3. Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100101, China

Abstract

Satellite laser altimetry technology, a novel space remote sensing technique, actively acquires high-precision elevation information about the Earth’s surface. However, the accuracy of laser altimetry can be compromised by alterations in the satellite-ground environment, thermal dynamics, and cosmic radiation. These factors may induce subtle variations in the installation and internal structure of the spaceborne laser altimeter on the satellite platform, diminishing measurement precision. In-orbit calibration is thus essential to enhancing the precision of laser altimetry. Through collaborative calculations between satellite and ground stations, we can derive correction parameters for laser pointing and ranging, substantially improving the accuracy of satellite laser altimetry. This paper introduces a sophisticated calibration method for laser altimeter pointing and ranging that utilizes dense control points. The approach interpolates discrete ground control point data into continuous simulated terrain using empirical Bayesian kriging, subsequently categorizing the data for either pointing or ranging calibration according to their respective functions. Following this, a series of calibration experiments are conducted, prioritizing “pointing” followed by “ranging” and continuing until the variation in the ranging calibration results falls below a predefined threshold. We employed experimental data from ground control points (GCPs) in Xinjiang and Inner Mongolia, China, to calibrate the GaoFen-7 (GF-7) satellite Beam 2 laser altimeter as per the outlined method. The calibration outcomes were then benchmarked against those gleaned from infrared laser detector calibration, revealing disparities of 1.12 s in the pointing angle and 2 cm in the ranging correction value. Post validation with ground control points, the measurement accuracy was refined to 0.15 m. The experiments confirm that the proposed calibration method offers accuracy comparable to that of infrared laser detector calibration and can facilitate the updating of 1:10,000 topographic maps utilizing stereo optical imagery. Furthermore, this method is more cost-effective and demands fewer personnel for ground control point collection, enhancing resource efficiency compared to traditional infrared laser detector calibration. The proposed approach surpasses terrain-matching limitations when calibrating laser ranging parameters and presents a viable solution for achieving frequent and high-precision in-orbit calibration of laser altimetry satellites.

Funder

National Natural Science Foundation of China

Publisher

MDPI AG

Subject

General Earth and Planetary Sciences

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3