Usefullness of Heparin Calibrated Anti-Xa Activity to Assess Anticoagulant Activity of Apixaban and Rivaroxaban in Emergency Patients Scheduled for Acute Interventions

Author:

Riahi Nada1,Rozen Laurence12ORCID,Demulder Anne12ORCID

Affiliation:

1. Department of Hematology, Laboratoire Hospitalier Universitaire de Bruxelles LHUB-ULB, Université Libre de Bruxelles ULB, 1020 Brussels, Belgium

2. Laboratory of Hematology, CHU-Brugmann, 1020 Brussels, Belgium

Abstract

(1) Background: Direct oral anticoagulants (DOACs) require monitoring in some critical clinical situations. The specific tests for DOAC monitoring are not yet available in all labs. The aim of this study was to evaluate if a unique, more widespread heparin-calibrated anti-Xa assay could be suitable to estimate the concentrations of apixaban and rivaroxaban in order to establish an algorithm helping our clinicians in their therapeutic decision for patients treated with DOACs in emergencies. (2) Methods: A first retrospective part allowed us to determine of a conversion factor between the measured DOAC concentration and the deducted anti-Xa heparin activity based on optic density. During the second prospective part, both DOAC concentration (ng/mL) and anti-Xa activity heparin (UI/mL) were measured on the same sample, and the previously determined conversion factor was applied to each UI/mL value. We then compared the calculated and measured DOAC concentration values. (3) Results: The analysis of the derivation cohort confirmed a good correlation, especially between the anti-Xa heparin activity and the apixaban concentrations (r = 0.97). Additionally, we determined heparin-calibrated anti-Xa assay cut-offs for invasive procedures at 0.3 UI/mL and for intravenous thrombolysis at 0.51 UI/mL using ROC curves with a sensitivity at 98% and specificity at 95% for 0.3 UI/mL and a sensitivity at 97.7% and specificity at 88.2% for the cut-off of 0.51 UI/mL. In the validation cohort, we confirmed the agreement between measured and calculated DOAC concentrations for the low values, especially around cut-offs with an excellent negative predictive value for 0.51 UI/mL (94% for apixaban and 100% for rivaroxaban) and a good negative predictive value for 0.3 UI/mL (83.3% for apixaban and 85.7% for rivaroxaban). (4) Conclusions: Our results confirm that it is possible to correctly predict or exclude the presence of apixaban/rivaroxaban in emergency situations when specific tests are not readily available.

Publisher

MDPI AG

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3