Thermal Imaging of Tongue Surface as a Prognostic Method in the Diagnosis of General Diseases—Preliminary Study

Author:

Wziątek-Kuczmik Daria1ORCID,Niedzielska Iwona1,Mrowiec Aleksandra2ORCID,Stanek Agata3ORCID,Gościniewicz Piotr4,Mrukwa-Kominek Ewa5ORCID,Cholewka Armand2

Affiliation:

1. Department of Cranio-Maxillofacial Surgery, Faculty of Medical Sciences, Medical University of Silesia, 40-055 Katowice, Poland

2. Faculty of Science and Technology, University of Silesia, 40-007 Katowice, Poland

3. Department and Clinic of Internal Medicine, Angiology and Physical Medicine, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Batorego 15 St, 41-902 Bytom, Poland

4. Department of Ophthalmology, Professor K. Gibiński University Clinical Center, Medical University of Silesia, 40-055 Katowice, Poland

5. Department of Ophthalmology, Faculty of Medical Sciences in Katowice, Medical University of Silesia, 40-055 Katowice, Poland

Abstract

The aim of this work was to develop an original method of thermographic measurement of tongue temperature as a prognostic method in the diagnosis of general diseases. This study examined the temperature distribution on the dorsal and apical surfaces of the tongue in patients with various general diseases and introduced a procedure for cooling the oral cavity. Patients with a high risk of systemic infections were referred to the Oral and Maxillofacial Surgery Outpatient Clinic of the Medical University of Silesia (SUM) in Katowice to identify potential foci of dental infections. They underwent an evaluation of their dentition as well as a prognostic tongue examination using the thermal camera FLIR T540 with a sensitivity of <0.03 K. The obtained results revealed statistically significant differences in the tongue average temperature parameters between the two study groups—healthy patients and patients with disorders. We obtained median temperatures for tongue dorsum (TD) of 35.8 °C and 35.2 °C for healthy patients and patients with disorders, respectively. Also, statistical differences have been obtained for tongue apex (TA) average temperatures. They were 35.5 °C and 34.0 °C for healthy and patients, respectively (p = 0.0001). Similar statistical results presented significant differences in the temperature difference (defined as DT = average temperature 10 min − average temperature 2 min after rinsing of the mouth) of the examined areas of the tongue between the healthy temperature and the unhealthy patient’s temperature. It seems that thermal imaging has potential in the prevention and diagnosis of general diseases.

Publisher

MDPI AG

Subject

General Medicine

Reference23 articles.

1. Application of thermography in medicine—Literature review;Modrzejewska;Pomeranian J. Life Sci.,2018

2. Infrared thermal imaging as noninvasive method of body temperature measurement in hospitalized and nonhospitalized children;Jung;Overv. Electrotechnical.,2013

3. new standards for devices used for the measurement of human body temperature;McEvoy;J. Med. Eng. Technol.,2010

4. Standardization of infrared thermal imaging in medicine and physiotherapy;Bauer;Acta Bio-Opt. Et Inform. Medica,2014

5. Ring EF, J., Jung, A., Kalicki, B., Zuber, J., Rustecka, A., and Vardasca, R. (2013). new standards for fever screening with thermal imaging system. J. Mech. Med. Biol., 13.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3