Performance Assessment of W-Band Radiometers: Direct versus Heterodyne Detections

Author:

Pascual Juan PabloORCID,Aja BeatrizORCID,Villa EnriqueORCID,Terán Jose Vicente,de la Fuente LuisaORCID,Artal EduardoORCID

Abstract

W-Band radiometers using intermediate frequency down-conversion (super-heterodyne) and direct detection are compared. Both receivers consist of two W-band low noise amplifiers and an 80-to-101 GHz filter, which conforms to the reception frequency band, in the front-end module. The back-end module of the first receiver comprises a subharmonic mixer, intermediate frequency (IF) amplification and a square-law detector. For direct detection, a W-Band detector replaces the mixer and the intermediate frequency detection stages. The performance of the whole receivers has been simulated requiring special techniques, based on data from the experimental characterization of each subsystem. In the super-heterodyne implementation a local oscillator at 27.1 GHz (with 8 dBm) with a x3 frequency multiplier is used, exhibiting an overall conversion gain around 48 dB, a noise figure around 4 dB, and an effective bandwidth over 10 GHz. In the direct detection scheme, slightly better noise performance is obtained, with a wider bandwidth, around 20 GHz, since there is no IF bandwidth limitation (~15 GHz), and even using the same 80-to-101 GHz filter, the detector can operate through the whole W-band. Moreover, W-band detector has higher sensitivity than the IF detector, increasing slightly the gain. In both cases, the receiver performance is characterized when a broadband noise input signal is applied. The radiometer characteristics have been obtained working as a total power radiometer and as a Dicke radiometer when an optical chopper is used to modulate the incoming signal. Combining this particular super-heterodyne or direct detection topologies and total power or Dicke modes of operation, four different cases are compared and discussed, achieving similar sensitivities, but better performances in terms of equivalent bandwidth and noise for the direct detection radiometer. It should be noted that this conclusion comes from a particular set of components, which we could consider as typical, but we cannot exclude other conclusions for different components, particularly for different mixers and detectors.

Funder

Spanish Ministry of Science and Innovation

Spanish Ministry of Economy and Competitiveness

University of Cantabria

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3