Abstract
In this study, a novel control approach for a doubly-fed induction generator (DFIG) is developed and applied to improve the system’s dynamic response and performance for providing high energy quality while avoiding harmonic accumulations. Because of its ease of implementation, field-oriented control (FOC) is frequently used. This control has great sensitivity to the machine’s parametric variations. For this reason, adaptive Backstepping control (ABC) is capable of preserving almost all of the performance and robustness properties. However, its analytical formulation has a problem. To overcome these disadvantages, the hybrid control (HC) is developed and verified to enable rapid response, complete reference tracking, and appropriate dynamic behavior with a low ripple level. This control is a combination of FOC’s and ABC’s control laws. The prepared control is explored by simulation testing using Matlab/Simulink and practical implementation using an FPGA board with actual turbine settings and a real wind profile of Dakhla City, Morocco. The results of hardware simulation show the efficacy of the HC in terms of speed and robustness, with a total harmonic distortion THD = 0.95, a value of THD that reveals the quality of the energy injected into the grid.
Subject
Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献