A Novel Method for ECG Signal Compression and Reconstruction: Down-Sampling Operation and Signal-Referenced Network
-
Published:2023-04-07
Issue:8
Volume:12
Page:1760
-
ISSN:2079-9292
-
Container-title:Electronics
-
language:en
-
Short-container-title:Electronics
Author:
Huang Rui12ORCID, Xue Xiaojun2, Xiao Renjie2, Bu Fan2
Affiliation:
1. Academy for Engineering & Technology, Fudan University, Shanghai 200433, China 2. Medical Health Information Center, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
Abstract
Objective. The wearable electrocardiogram (ECG) monitoring device is an effective tool for diagnosing intermittent heart diseases. However, the massive amount of ECG data increases power consumption during wireless transmission, thereby reducing the monitoring duration of the wearable device. Here, we presented a novel method to solve this problem. Method. To reduce the data size, we used a down-sampling operation to compress signals. Then, we designed a signal-referenced network to reconstruct the original signals from the compressed ones. We validated the proposed method on the China Physiological Signal Challenge 2018 database, used the root mean square error (RMSE) to evaluate the performance of the proposed network, and evaluated the effectiveness of the reconstructed signals via the F1-score of an ECG signal classifier. Main Result. The classifier used in this paper achieved an F1-score of 84% on 500 Hz signals reconstructed from 25 Hz, 89% from 50 Hz, 90% from 125 Hz, and 95% from 250 Hz. The RMSE of these four sampling rates was 0.10 mV, 0.08 mV, 0.05 mV, and 0.04 mV, respectively. Significance. The experimental result shows that the proposed network has a good performance when reconstructing signals. Furthermore, our method can remove the computational load of compressing signals from wearable devices.
Funder
Ministry of Science and Technology
Subject
Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering
Reference23 articles.
1. How useful is the smartwatch ECG?;Isakadze;Trends Cardiovasc. Med.,2020 2. Hsu, C.-C., Lin, B.-S., He, K.-Y., and Lin, B.-S. (2019). Design of a Wearable 12-Lead Noncontact Electrocardiogram Monitoring System. Sensors, 19. 3. Bleda, A.L., Melgarejo-Meseguer, F.M., Gimeno-Blanes, F.J., Garcia-Alberola, A., Rojo-Alvarez, J.L., Corral, J., Ruiz, R., and Maestre-Ferriz, R. (2019). Enabling Heart Self-Monitoring for All and for AAL-Portable Device within a Complete Telemedicine System. Sensors, 19. 4. Vavrinsky, E., Subjak, J., Donoval, M., Wagner, A., Zavodnik, T., and Svobodova, H. (2020). Application of Modern Multi-Sensor Holter in Diagnosis and Treatment. Sensors, 20. 5. Assessment of Signal Quality Measured with a Smart 12-lead Ecg Acquisition T-shirt;Fouassier;Ann. Noninvasive Electrocardiol.,2020
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|