Affiliation:
1. School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2. China Southern Power Grid Co., Ltd., EHV Transmission Company, Guangzhou 510700, China
Abstract
The arrester plays an important role in the protection of the DC transmission system, and its thermal characteristics under different operating conditions greatly affect its performance. To study the thermal characteristics of multicolumn parallel arresters under extreme operating conditions in a DC system, considering the influence of SF6 fluid, the structural parameters of the ±500 kV Niu Cong DC transmission project were applied for this research. Firstly, a 3D model of the four-column parallel zinc oxide arrester installed on the neutral bus of the ±500 kV Niu Cong DC transmission project was built in ANSYS to analyze its thermal conduction. Then, the electromagnetic transient model of the Niu Cong DC transmission system was established in PSCAD to study the withstood energy of a four-column parallel zinc oxide arrester under 22 typical fault conditions in three operation modes. Based on the extreme operating conditions obtained, simulations of steady-state and transient thermal characteristics were performed considering the influence of SF6 fluid flow on the heat dissipation of the arrester. Finally, the field-test temperature test on the four-column parallel zinc oxide arrester was carried out to validate the effectiveness of the proposed simulation model and calculation method, with simulation data matching well with the field-test data. The results also conclude the thermal characteristics findings to reveal the thermal conduction of multicolumn arresters under extreme operating conditions.
Subject
Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering
Reference33 articles.
1. Internal overvoltage and insulation coordination of electrode line in HVDC project;Xie;High Volt. Eng.,2018
2. Mechanism and Application of Arrester Block Voltage Division to Lightning Transient Voltage Monitoring in Substation Transformers;Zhang;IEEE Trans. Electromagn. Compat.,2019
3. Study on overvoltage of UHV DC grounding line;Liu;High Volt. Eng.,2018
4. AC Intrusion Overvoltage Protection in Secondary DC System Based on Zinc Oxide Arrester;Zhao;Insul. Surge Arresters,2021
5. Research on Eddy Current Loss and Fluid-solid Coupling Heat Transfer in the End Region of Synchronous Condenser for UHV Transmission;Wang;Proc. CSEE,2022
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献