Abstract
In this paper, a proposed numerical frozen permeability modeling procedure is fully derived to accurately estimate the parameters of two variants of wound-field flux modulation machines (WF-FMMs) namely: wound-field flux switching machine (WF-FSM) and DC-excited vernier reluctance machine (DC-VRM). During the procedure, the contribution of saturation to the variation of the machine parameters is investigated. The parameter variation effects on the machine performance is also investigated. It is shown that analysis of WF-FMMs is better understood by using the proposed procedure which computes accurately the machine parameters.
Subject
Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献