Research on a Multi-Channel High-Speed Interferometric Signal Acquisition System

Author:

Huang Jingyu12,Chen Ren13,Xu Zhijing2ORCID,Wang Zhanhu1,Gu Mingjian1,Chen Yaxuan14,Sun Jun12,Lin Yinghui12

Affiliation:

1. State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China

2. College of Information Engineering, Shanghai Maritime University, Shanghai 201306, China

3. Joint Lab of Calibration and Metrology Technology of Infrared Remote Sensing, Shanghai Institute of Technical Physics, Shanghai 200083, China

4. Key Laboratory of Polar Materials and Devices (MOE), Department of Electronics, East China Normal University, Shanghai 200241, China

Abstract

In order to capture the large-scale interferometric signal generated by the space-borne interferometric infrared Fourier spectrometer (IRIFS) in real time, and overcome the limitations of insufficient sampling rate, transmission rate, and significant signal noise in current equipment, a multi-channel high-speed acquisition system for large-scale interferometric signals is designed. A high-performance analog-to-digital converter (ADC) oversampling scheme is designed, which can realize up to 8 synchronous acquisition channels and has a maximum sampling rate of 125 Msps/Ch to ensure the acquisition of interferometric signals. The scheme of jesd204b inter-board transmission and optical fiber terminal transmission is designed. The inter-board transmission rate is 12.5 Gbps, and the terminal transmission rate is 10 GB/s to ensure high-speed data transmission. A hardware filter is designed to realize spatial noise processing of interference signals and ensure the accuracy of acquisition results. The dynamic performance of the data acquisition (DAQ) card is analyzed using discrete Fourier transform in the frequency domain. The spurious free dynamic range (SFDR) is 84 dB, the signal-to-noise ratio (SNR) is 72.7 dB, and the cross-talk is −81.6 dB, which verifies the dynamic stability of the DAQ card. Finally, the infrared radiation in real space is measured. The average ΔNESR of long wave reaches 48 mW∗m−2∗sr−1, and the average ΔNESR of medium wave reaches 12.3 mW∗m−2∗sr−1, which verifies the reliability of the system performance. The system is of great significance for large-scale infrared interferometric signal acquisition, and has strong practical application value in multi-channel synchronization, real-time high-speed acquisition, and high-speed data transmission.

Funder

National Key Research and Development Program of China

China’s National Key Special Earth Observation and Navigation Project “Atmospheric radiation hyper-spectral detection technology”

Ministry of Science and Technology of the People’s Republic of China

Mid-infrared Observation System for Accurate Measurement of Solar Magnetic Field, National Natural Science Foundation of China

Publisher