Abstract
In this paper, the effect of common-mode voltage generated in the three-level quasi-switched boost T-type inverter is minimized by applying the proposed space-vector modulation technique, which uses only medium vectors and zero vector to synthesize the reference vector. The switching sequence is selected smoothly for inserting the shoot-through state for the inverter branch. The shoot-through vector is added within the zero vector in order to not affect the active vectors as well as the output voltage. In addition, the shoot-through control signal of active switches of the impedance network is generated to ensure that its phase is shifted 90 degrees compared to shoot through the signal of the inverter leg, which provides an improvement in reducing the inductor current ripple and enhancing the voltage gain. The effectiveness of the proposed method is verified through simulation and experimental results. In addition, the superiority of the proposed scheme is demonstrated by comparing it to the conventional pulse-width modulation technique.
Subject
Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献