Abstract
High efficiency and the power factor of power converters, are very important factors which can improve power system quality. In particular, research on improving low efficiency and the power factor at light-load conditions is essential. A boost power factor correction (PFC) is most commonly used in home appliances, with several operations being at light-loads; the critical conduction mode (CRM) control, fixed ON-time control, and valley detection technique are mainly applied to PFC control. However, these control schemes have the following problems: (1) low efficiency, due to sudden increase in switching frequency at light-loads; and (2) low power factor, due to switching ON-time limitation. This paper presents a new valley detection method that can actively extend the fixed ON-time to overcome these problems. Furthermore, a new valley point detection circuit and an ON-time extension signal generation circuit are proposed and described in detail. The superiority of the proposed method is demonstrated via comparison with two existing CRM PFC control methods, namely fixed ON-time (conventional#1) and existing valley detection (conventional#2) methods. Experimental results at 20% load demonstrate that the proposed method shows an efficiency improvement of 2.1%, compared with the fixed ON-time strategy; and a power factor improvement of 34.9%, compared with the existing valley detection strategy.
Subject
Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献