Calculation Method of DC Fault Overvoltage Peak Value for Multi-Send HVDC Systems with Wind Power

Author:

Li Fan1,Liu Dong1,Han Xiaonan1,Qin Boyu2ORCID,Liu Zhongjian1,Yu Haoyang1,Zhang De34,Su Xiaofan34,Wang Mingjie5

Affiliation:

1. State Grid Economic and Technological Research Institute Co., Ltd., Beijing 102209, China

2. Department of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China

3. Hunan Key Laboratory of Energy Internet Supply-Demand and Operation, Changsha 410082, China

4. State Grid Hunan Electric Power Company Limited Economic & Technical Research Institute, Changsha 410029, China

5. Power Dispatching Control Center of Guizhou Power Grid Co., Ltd., Guiyang 550002, China

Abstract

Commutation failure (CF) and DC blocking (DCB) faults are common occurrences in high-voltage direct current (HVDC) systems, and their impact on the power grid can be significant due to sudden power fluctuations. These issues pose particular challenges in multi-send HVDC systems due to the intricate interaction between AC and DC components. To tackle these challenges, this paper proposes a method for analyzing the peak overvoltage at the converter bus resulting from DC faults in multi-send HVDC systems. The proposed method comprehensively considers the influence of DC/DC coupling and wind turbine low-voltage ride through (LVRT) characteristics on overvoltage. It offers a straightforward approach to calculate the peak overvoltage following a DC fault without the need for complex modeling or dynamic simulation software. By leveraging the equivalent parameters of the AC system and operational parameters of the DC system, the method effectively quantifies the overvoltage. The primary objective of this study is to address multi-send HVDC systems and establish computational formulas that enable a quantitative assessment of transient overvoltage resulting from DC faults. The analysis explores several influencing factors, uncovering that fault-induced overvoltage is influenced by aspects such as system strength and wind turbine reactive power dynamics. In a single-send HVDC system, the level of overvoltage in the system is primarily affected by the short-circuit ratio. A higher short-circuit ratio results in a lower overvoltage level. On the other hand, in multi-send HVDC systems, the overvoltage level is determined by the equivalent impedance of the individual systems. In DC systems where turbines are present in the DC near zone, the overvoltage level at the converter bus is influenced by the power characteristics of the turbines during the LVRT. To validate the accuracy of the proposed method, a comprehensive verification process is conducted. Through this research, the paper aims to contribute to the understanding and management of transient overvoltage in multi-send HVDC systems. By considering relevant factors and employing an equivalent model, the proposed method offers a practical approach for assessing overvoltage and facilitating the design and operation of such systems.

Funder

Science and Technology Project of the State Grid Corporation of China

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3