Affiliation:
1. School of Innovation, Design and Engineering, Mälardalen University, P.O. Box 883, 721 23 Västerås, Sweden
Abstract
The extraction of relevant features from the photoplethysmography signal for estimating certain physiological parameters is a challenging task. Various feature extraction methods have been proposed in the literature. In this study, we present a novel fiducial point extraction algorithm to detect c and d points from the acceleration photoplethysmogram (APG), namely “CnD”. The algorithm allows for the application of various pre-processing techniques, such as filtering, smoothing, and removing baseline drift; the possibility of calculating first, second, and third photoplethysmography derivatives; and the implementation of algorithms for detecting and highlighting APG fiducial points. An evaluation of the CnD indicated a high level of accuracy in the algorithm’s ability to identify fiducial points. Out of 438 APG fiducial c and d points, the algorithm accurately identified 434 points, resulting in an accuracy rate of 99%. This level of accuracy was consistent across all the test cases, with low error rates. These findings indicate that the algorithm has a high potential for use in practical applications as a reliable method for detecting fiducial points. Thereby, it provides a valuable new resource for researchers and healthcare professionals working in the analysis of photoplethysmography signals.
Subject
Electrical and Electronic Engineering,Computer Networks and Communications,Hardware and Architecture,Signal Processing,Control and Systems Engineering
Reference39 articles.
1. Photoplethysmography and Its Application in Clinical Physiological Measurement;Allen;Physiol. Meas.,2007
2. Secondary Peak Detection of PPG Signal for Continuous Cuffless Arterial Blood Pressure Measurement;He;IEEE Trans. Instrum. Meas.,2014
3. Multiparameter Respiratory Rate Estimation from the Photoplethysmogram;Karlen;IEEE Trans. Biomed. Eng.,2013
4. A Time-Frequency Domain Approach of Heart Rate Estimation from Photoplethysmographic (PPG) Signal;Islam;Biomed. Signal. Process. Control,2017
5. Fukushima, H., Kawanaka, H., Bhuiyan, M.S., and Oguri, K. (September, January 28). Estimating Heart Rate Using Wrist-Type Photoplethysmography and Acceleration Sensor While Running. Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC, San Diego, CA, USA.
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献