Swine Small Intestine Sealing Performed by Different Vessel Sealing Devices: Ex-Vivo Test

Author:

Lacitignola LucaORCID,Imperante AnnaritaORCID,Trisciuzzi Rodrigo,Zizzo NicolaORCID,Crovace Alberto Maria,Staffieri FrancescoORCID

Abstract

This study aimed to evaluate the sealing quality of swine small intestine using different laparoscopic radiofrequency vessel sealing devices (two 5 mm: RFVS-1 and -2; one 10 mm: RFVS-3) and a harmonic scalpel (HS) compared to golden standard closure technique. The study was divided into two arms. In study arm 1: n = 50 swine intestinal loops (10 per group) were transected with each instrument and the loops in which the devices provided complete sealing, at the gross inspection, were tested for maximum burst pressure (BP) and histological evaluation and compared to an automatic linear stapler. After the BP tests, the devices that achieved significantly lower BP values were excluded from the second arm. The RFVS-1 and -3 provided statistically significant results and were used in study arm 2, to obtain full-thickness biopsies along the antimesenteric border of the loop and were compared with hand-sewn intestinal closure (n = 30; 10 per group). The biopsies were histologically evaluated for thermal injury and diagnostic features, and intestinal loops tested for BP. RFVS-3 achieved comparable results (69.78 ± 4.23 mmHg, interquartile range (IQR) 5.8) to stapler closing technique (71.09 ± 4.22 mmHg, IQR 4.38; p > 0.05), while the RFVS-1 resulted in significantly (p < 0.05) lower BP (45.28 ± 15.23 mmHg, IQR 24.95) but over the physiological range, conversely to RFVS-2 (20.16 ± 7.19 mmHg, IQR 12.02) and HS (not measurable). RFVS-3 resulted not significantly different (p > 0.05) (45.09 ± 8.75 mmHg, IQR 10.48) than Suture (35.71 ± 17.51 mmHg, IQR 23.77); RFVS-1 resulted significantly lower values (23.96 ± 10.63 mmHg, IQR 9.62; p < 0.05). All biopsies were judged diagnostic. Data confirmed that RFVS-1 and -3 devices provided suitable intestinal sealing, with BP pressures over the physiological range. Conversely, the HS and RFVS-2 should not be considered for intestinal sealing. RFVS devices could be employed to obtain small intestine stump closure or full-thickness biopsies. However, further studies should be performed in live animals to assess the role of the healing process.

Publisher

MDPI AG

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3