Relevance of the Operator’s Experience in Conditioning the Static Computer-Assisted Implantology: A Comparative In Vitro Study with Three Different Evaluation Methods

Author:

Pellegrino GerardoORCID,Lizio GiuseppeORCID,D’Errico Filippo,Ferri Agnese,Mazzoni Annalisa,Bianco Federico Del,Stefanelli Luigi Vito,Felice Pietro

Abstract

The present study aimed to evaluate the influence of manual expertise on static computer-aided implantology (s-CAI) in terms of accuracy and operative timings. After the cone-beam CT (CBCT) scanning of eleven mandibular models, a full-arch rehabilitation was planned, and two different skilled operators performed s-CAI. The distances between the virtual and actual implant positions were calculated considering the three spatial vectorial axes and the three-dimensional Euclidean value for the entry (E) and apical (A) points, along with the axis orientation differences (Ax). These values emerged from the overlapping of the pre-op CBCT to post-op CBCT data (method 1), from scanning the data from the laboratory scanner (method 2), and from the intra-oral scanner (method 3) and were correlated with the operators’ expertise and operative timings. The mean values for accuracy from the three methods were: E = 0.57 (0.8, 0.45, 0.47) mm, A = 0.6 (0.8, 0.48, 0.49) mm, and Ax 1.04 (1.05,1.03,1.05) ° for the expert operator; and E = 0.8 (0.9, 0.87, 0.77), A = 0.95 (1.02, 0.95, 0.89), and Ax =1.64 (1.78, 1.58, 1.58) for the novice. The mean value of the operative timings was statistically inferior for the expert operator (p < 0.05), with an improved accuracy over time for both operators. A significant difference (p < 0.05) emerged between method 1 and methods 2 and 3 for seven of the nine variables, without differences between the evaluations from the two scanners. The support from digital surgical guides does not eliminate the importance of manual expertise for the reliability and the shortening of the surgical procedure, and it requires a learning pathway over time.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3