Optimization Method to Predict Optimal Noise Reduction Parameters for the Non-Local Means Algorithm Based on the Scintillator Thickness in Radiography

Author:

Cha Bo Kyung1,Lee Kyeong-Hee1,Lee Youngjin2,Kim Kyuseok3

Affiliation:

1. Precision Medical Device Research Center, Korea Electrotechnology Research Institute (KERI), 111 Hanggaul-ro, Sangnok-gu, Ansan-si 15588, Republic of Korea

2. Department of Radiological Science, Gachon University, 191 Hambangmoe-ro, Yeonsu-gu, Incheon 21936, Republic of Korea

3. Department of Biomedical Engineering, Eulji University, 553 Sanseong-daero, Sujeong-gu, Seongnam-si 13135, Republic of Korea

Abstract

The resulting image obtained from an X-ray imaging system depends significantly on the characteristics of the detector. In particular, when an X-ray image is acquired by thinning the detector, a relatively large amount of noise inevitably occurs. In addition, when a thick detector is used to reduce noise in X-ray images, blurring increases and the ability to distinguish target areas deteriorates. In this study, we aimed to derive the optimal X-ray image quality by deriving the optimal noise reduction parameters based on the non-local means (NLM) algorithm. The detectors used were of two thicknesses (96 and 140 μm), and images were acquired based on the IEC 62220-1-1:2015 RQA-5 protocol. The optimal parameters were derived by calculating the edge preservation index and signal-to-noise ratio according to the sigma value of the NLM algorithm. As a result, a sigma value of the optimized NLM algorithm (0.01) was derived, and this algorithm was applied to a relatively thin X-ray detector system to obtain appropriate noise level and spatial resolution data. The no-reference-based blind/referenceless image spatial quality evaluator value, which analyzes the overall image quality, was best when using the proposed method. In conclusion, we propose an optimized NLM algorithm based on a new method that can overcome the noise amplification problem in thin X-ray detector systems and is expected to be applied in various photon imaging fields in the future.

Funder

Korea Electrotechnology Research Institute

Korea Medical Device Development

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3