The Possibility of Managed Aquifer Recharge (MAR) for Normal Functioning of the Public Water-Supply of Zagreb, Croatia

Author:

Meaški HrvojeORCID,Biondić RankoORCID,Loborec Jelena,Oskoruš Dijana

Abstract

With its quantities of groundwater, the Zagreb aquifer is an irreplaceable water-supply resource that forms the basis of the water-supply of Zagreb, the capital and largest city of the Republic of Croatia. The depth of the Zagreb aquifer system is about 100 m at the deepest part, and the two main aquifers of the aquifer system can be separated vertically by low-permeable clay deposits. In the area of the Zagreb aquifer, there are several active and reserve public water-supply sites, the largest of which are Mala Mlaka and Petruševec. The groundwater level of the Zagreb aquifer is directly related to the water levels of the Sava River, so any erosive change in the Sava riverbed decreases the groundwater levels in the aquifer. In the last 50 years, the groundwater levels in the Zagreb aquifer have decreased significantly, being most pronounced in the area of the Mala Mlaka water-supply site. This has affected the normal functioning of the public water-supply because the suction baskets of the pumps in the dug wells at the Mala Mlaka water-supply site occasionally remain partially or completely in the unsaturated aquifer zone during low groundwater levels, which reduces capacity or prevents pumping from these water-supply facilities. Immediately next to the Mala Mlaka water-supply site is the Sava-Odra Canal, which was built to protect Zagreb from flooding and into which the Sava River flows when its flow rate exceeds 2350 m3/s. This reduces the flow rate of the Sava River near Zagreb and the possibility of flooding urban areas. To prevent problems with groundwater levels at the Mala Mlaka water-supply facilities and to enable normal water-supply, even in extremely dry periods, several variants of managed aquifer recharge (MAR) are proposed here. In order to determine the optimal solution for MAR and to enable the normal functioning of one of the main sites of water-supply in the Zagreb water-supply system. Groundwater flow for the period of 2006 to 2010 was simulated for six different variants of MAR. One assumes a constant potential in the Sava-Odra Canal, three are related to recharge from the Sava-Odra Canal with different backwater levels in the infiltration facility (elevations of 114, 114.5, and 115 m a.s.l.), and two with three absorption wells upstream of the Mala Mlaka water pumping station (injection of 300 L/s each and 500 L/s each). The most favorable method to recharge artificially the Zagreb aquifer near the Mala Mlaka pumping station is achieved with an infiltration facility using an elevation of 115 m a.s.l. The use of such a facility will enable the smooth operation of the water pumping station and the possibility of increasing the pumping quantities at the Mala Mlaka water pumping station for the future development of the area.

Funder

Croatian Waters

Publisher

MDPI AG

Subject

Water Science and Technology,Aquatic Science,Geography, Planning and Development,Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3