The Influence of Stride Selection on Gait Parameters Collected with Inertial Sensors

Author:

Ensink Carmen J.12,Smulders Katrijn1,Warnar Jolien J. E.1,Keijsers Noël L. W.123

Affiliation:

1. Department of Research, Sint Maartenskliniek, 6500 GM Nijmegen, The Netherlands

2. Department of Sensorimotor Neuroscience, Donders Institute for Brain, Cognition and Behaviour, Radboud University, 6500 HB Nijmegen, The Netherlands

3. Department of Rehabilitation, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Center, 6500 HB Nijmegen, The Netherlands

Abstract

Different methods exist to select strides that represent preferred, steady-state gait. The aim of this study was to identify the effect of different stride-selection methods on spatiotemporal gait parameters to analyze steady-state gait. A total of 191 patients with hip or knee osteoarthritis (aged 38–85) wearing inertial sensors walked back and forth over 10 m for two minutes. After the removal of strides in turns, five stride-selection methods were compared: (ALL) include all strides, others removed (REFERENCE) two strides around turns, (ONE) one stride around turns, (LENGTH) strides <63% of median stride length, and (SPEED) strides that fall outside the 95% confidence interval of gait speed over the strides included in REFERENCE. Means and SDs of gait parameters were compared for each trial against the most conservative definition (REFERENCE). ONE and SPEED definitions resulted in similar means and SDs compared to REFERENCE, while ALL and LENGTH definitions resulted in substantially higher SDs of all gait parameters. An in-depth analysis of individual strides showed that the first two strides after and last two strides before a turn were significantly different from steady-state walking. Therefore, it is suggested to exclude the first two strides around turns to assess steady-state gait.

Funder

PPP Allowance

Smith and Nephew, Hoofddorp

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3