Abstract

In patients undergoing percutaneous coronary intervention, the second-generation drug-eluting stents (DES) are considered the gold standard of care for revascularization. By reducing neointimal hyperplasia, drug-eluting coronary stents decrease the need for repeat revascularizations compared with conventional coronary stents without an antiproliferative drug coating. It is important to note that early-generation DESs were associated with an increased risk of very late stent thrombosis, most likely due to delayed endothelialization or a delayed hypersensitivity reaction to the polymer. Studies have shown a lower risk of very late stent thrombosis with developing second-generation DESs with biocompatible and biodegradable polymers or without polymers altogether. In addition, research has indicated that thinner struts are associated with a reduced risk of intrastent restenosis and angiographic and clinical results. A DES with ultrathin struts (strut thickness of 70 µm) is more flexible, facilitates better tracking, and is more crossable than a conventional second-generation DES. The question is whether ultrathin eluting drug stents suit all kinds of lesions. Several authors have reported that improved coverage with less thrombus protrusion reduced the risk of distal embolization in patients with ST-elevation myocardial infarction (STEMI). Others have described that an ultrathin stent might recoil due to low radial strength. This could lead to residual stenosis and repeated revascularization of the artery. In CTO patients, the ultrathin stent failed to prove non-inferiority regarding in-segment late lumen loss and showed statistically higher rates of restenosis. Ultrathin-strut DESs with biodegradable polymers have limitations when treating calcified (or ostial) lesions and CTOs. However, they also possess certain advantages regarding deliverability (tight stenosis, tortuous lesions, high angulation, etc.), ease of use in bifurcation lesions, better endothelialization and vascular healing, and reducing stent thrombosis risk. In light of this, ultrathin-strut stents present a promising alternative to existing DESs of the second and third generation. The aims of the study are to compare ultrathin eluting stents with second- and third-generation conventional stents regarding procedural performance and outcomes based on different lesion types and specific populations.

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3