Guided Access through Ceramic Crowns with Fiberglass Post Removal in Lower Molars: An In Vitro Study

Author:

Fachin Gustavo Freitas1ORCID,Dinato Thiago Revillion2,Prates Frederico Ballvé3,Connert Thomas4ORCID,Pelegrine Rina Andrea1ORCID,Bueno Carlos Eduardo da Silveira1

Affiliation:

1. Department of Endodontics, São Leopoldo Mandic Dental Research Center, Campinas 13045-755, SP, Brazil

2. Department of Implantology, Brazilian Dental Association, Porto Alegre 90470-130, RS, Brazil

3. Specialist in Dental Radiology and Imaging through São Leopoldo Mandic (Sobracursos), Porto Alegre 90050-240, RS, Brazil

4. Department of Periodontology, Endodontology and Cariology, University Center for Dental Medicine UZB, University of Basel, 4058 Basel, Switzerland

Abstract

This in vitro study evaluated the accuracy of guided endodontics for the removal of intraradicular fiberglass posts from posterior mandibular teeth and the influence of the operator’s experience in this procedure. Forty root-filled mandibular first molars with an intraradicular fiberglass post were mounted onto 20 mandibular models. Guides for access were made following surface scanning and cone-beam computed tomography (CBCT) using CoDiagnostix software. The models were randomly divided between two operators (n = 20). One was an inexperienced dental surgeon (IN), and the other was a dentist experienced in the guided technique (EX). A postoperative CBCT scan was superimposed on the initial planning, and the means were calculated for the angle and for 3D deviation. The 95% confidence interval (CI) was calculated, and differences between groups were assessed by a t-test. The mean deviation angle was 2.54° (0–5.85°) for IN and 1.55° (0–2.85°) for EX. The mean 3D deviation was 0.44 mm (0.14–0.73 mm) for IN and 0.33 mm (0.11–0.76 mm) for EX. The means of the angle and 3D deviation were significantly different (p = 0.008 and p = 0.049). Guided endodontics was influenced by the operator and allowed access for removing intraradicular fiberglass posts with minimal deviation and greater accuracy for an experienced operator compared with an inexperienced one.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3