Computational Fluid Dynamics (CFD) and Finite Element Analysis (FEM) of a Customized Stent-Graft for Endovascular (EVAR) Treatment of Abdominal Aortic Aneurism (AAA)

Author:

Bologna Emanuela1ORCID,Dinoto Ettore2,Di Simone Francesco3,Pecoraro Felice24ORCID,Ragusa Sara3,Siciliano Katia3,Zingales Massimiliano1ORCID

Affiliation:

1. Dipartimento di Ingegneria, Università degli Studi di Palermo, Viale delle Scienze Ed. 8, 90128 Palermo, Italy

2. Vascular Surgery Unit—AOUP ‘p. Giaccone’, 90127 Palermo, Italy

3. Advanced Medical Engineering Devices srl, Viale delle Scienze, 90128 Palermo, Italy

4. Department of Surgical, Oncological and Oral Sciences, University of Palermo, 90133 Palermo, Italy

Abstract

Background: The treatment of abdominal aortic aneurysm (AAA) is today commonly treated by inserting a stent-graft by the endovascular route, without resorting to open surgery. However, some clinical cases do not allow this less invasive approach, meaning that the stent-graft cannot be inserted and open surgery is used. Methods: In the study, we propose a fluid–structure interaction (FSI) analysis of an aneurysmatic aorta that could not be treated with Endovascular Aneurysm Repair (EVAR). The vessel is reconstructed through segmentation from CT scans and subsequently modeled on CAD software to create the surface and thickness of the vessel itself. Subsequently, we proceeded to carry out Computational Fluid Dynamics (CFD) and FSI simulation. We propose a computational study on a vessel geometry that is faithful to reality and customized. Results: Hemodynamic variable results of the carried out simulations indicate that low velocity and consequently very low WSS areas located in aneurysmal site are no longer found when conventional or patient-specific grafts are inserted. The wall stress distribution of aorta FEM analysis enabled the identification of the area at risk of failure, that is, in the posterior part of the aneurysm (∼107 Pa), while FSI analysis of the patient-specific graft led to a uniform von Mises stresses distribution (∼105 Pa), except for the junctions where peak stress occurred. Conclusion: The importance of this study is to highlight the benefits of the personalized stent/graft. As the authors expected, the study shows the numerous benefits of the customized stent/graft in terms of blood flow trend and wall stress compared to a traditional stent/graft by supporting the tendency to want to shift the target towards customized stents/grafts, also in the vascular surgery sector.

Funder

MUR

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3