Abstract
Leak detection and location in a gas distribution network are significant issues. The acoustic emission (AE) technique can be used to locate a pipeline leak. The time delay between two sensor signals can be determined by the cross-correlation function (CCF), which is a measure of the similarity of two signals as a function of the time delay between them. Due to the energy attenuation, dispersion effect and reverberation of the leakage-induced signals in the pipelines, the CCF location method performs poorly. To improve the leakage location accuracy, this paper proposes a modified leakage location method based on the AE signal, and combines the modified generalized cross-correlation location method and the attenuation-based location method using multilayer perceptron neural networks (MLPNN). In addition, the wave speed was estimated more accurately by the peak frequency of the leakage-induced AE signal in combination with the group speed dispersive curve of the fundamental flexural mode. To verify the reliability of the proposed location method, many tests were performed over a range of leak-sensor distances. The location results show that compared to using the CCF location method, the MLPNN locator reduces the average of the relative location errors by 14%, therefore, this proposed method is better than the CCF method for locating a gas pipe leak.
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
21 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献