Lighting Up the Tumor—Fluorescein-Guided Resection of Gangliogliomas

Author:

Höhne JuliusORCID,Acerbi Francesco,Falco Jacopo,Akçakaya Mehmet Osman,Schmidt Nils OleORCID,Kiris Talat,de Laurentis Camilla,Ferroli Paolo,Broggi MorganORCID,Schebesch Karl-Michael

Abstract

(1) Background: Gangliogliomas comprise a small number of brain tumors. They usually present as World Health Organization (WHO) grade I, and they delineate on gadolinium-enhanced MRI; the surgical goal is wide radical resection, and the course thereafter is usually benign. Fluorescein sodium (FL) tends to accumulate in areas with altered blood–brain barrier (BBB). Thus far, the results provided by prospective and retrospective studies show that the utilization of this fluorophore may be associated with better visualization and improvement of resection for several tumors of the central nervous system. In this study, we retrospectively studied the effect of fluorescein sodium on visualization and resection of gangliogliomas. (2) Methods: Surgical databases in three neurosurgical departments (Regensburg University Hospital; Besta Institute, Milano, Italy; and Liv Hospital, Istanbul, Turkey), with approval by the local ethics committee, were retrospectively reviewed to find gangliogliomas surgically removed by a fluorescein-guided technique by the aid of a dedicated filter on the surgical microscope from April 2014 to February 2020. Eighteen patients (13 women, 5 men; mean age 22.9 years, range 3 to 78 years) underwent surgical treatment for gangliogliomas during 19 operations. Fluorescein was intravenously injected (5 mg/kg) after general anesthesia induction. Tumors were removed using a microsurgical technique with the YELLOW 560 Filter (YE560) (KINEVO/PENTERO 900, Carl Zeiss Meditec, Oberkochen, Germany). (3) Results: No side effects related to fluorescein occurred. In all tumors, contrast enhancement on preoperative MRI correlated with bright yellow fluorescence during the surgical procedure (17 gangliogliomas WHO grade I, 1 ganglioglioma WHO grade II). Fluorescein was considered helpful by the operating surgeon in distinguishing tumors from viable tissue in all cases (100%). Biopsy was intended in two operations, and subtotal resection was intended in one operation. In all other operations considered preoperatively eligible, gross total resection (GTR) was achieved in 12 out of 16 (75%) instances. (4) Conclusions: The use of FL and YE560 is a readily available method for safe fluorescence-guided tumor resection, possibly visualizing tumor margins intraoperatively similar to contrast enhancement in T1-weighted MRI. Our data suggested a positive effect of fluorescein-guided surgery on intraoperative visualization and extent of resection during resection of gangliogliomas.

Publisher

MDPI AG

Subject

General Medicine

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3