Assessing Jump Performance: Intra- and Interday Reliability and Minimum Difference of Countermovement Jump and Drop Jump Outcomes, Kinetics, Kinematics, and Jump Strategy

Author:

González-García Jaime12ORCID,Conejero Manuel1,Gutiérrez-Hellín Jorge1ORCID

Affiliation:

1. Exercise and Sport Sciences, Faculty of Health Science, Universidad Francisco de Vitoria, 28223 Pozuelo, Spain

2. Faculty of Health Science, Camilo José Cela University, 28692 Madrid, Spain

Abstract

Understanding the reliability of jump testing is essential to determine the neuromuscular progress of athletes and make informed decisions. This study aimed to assess the reliability of several countermovement jump (CMJ) and drop jump (DJ) test metrics in female volleyball players. Sixteen (n = 16) semi-professional female volleyball players participated in this test-retest study. Intrasession and intersession reliability of CMJ and DJ metrics were evaluated using a randomized cross-over design. A dual force platform was used to collect CMJ and DJ data, and several dependent variables were calculated using forward dynamics. Intraclass correlation coefficients (ICC), coefficients of variation (CV), and minimum difference (MD) were calculated to assess intra- and interday reliability. During the same testing, the third attempt consistently yielded the highest values for both tests in jump height but presented excellent reliability (CMJ: ICC [95%CI] = 0.97 [0.93–0.99]; CV [95%CI] = 4.1% [1.2–7.0]; MD95 = 3.5 cm; MD90 = 2.9 cm; DJ: ICC [95%CI] = 0.91 [0.77–0.97]; CV [95%CI] = 6.7% [1.9–11.5]; MD95 = 6.0 cm; MD90 = 5.0 cm). CMJ height exhibited excellent reliability between sessions (ICC [95%CI] = 0.93 [0.81–0.97]; CV [95%CI] = 3.8% [1.1–6.4]; MD95 = 3.5 cm; MD90 = 3.0 cm), whereas DJ height demonstrated slightly lower but still acceptable intersession reliability (ICC [95%CI] = 0.81 [0.55–0.93]; CV [95%CI] = 6.1% [1.7–10.4]; MD95 = 5.2 cm; MD90 = 4.4 cm). Intersession reliability for CMJ kinetics and kinematics was excellent for 13 of the 24 metrics assessed. For DJ, only concentric (ICC [95%CI] = 0.91 [0.76–0.97]; CV [95%CI] = 3.0% [0.9–5.2]; MD95 = 15 Ns; MD90 = 12.6 Ns) and eccentric impulses (ICC [95%CI] = 0.99 [0.96–0.99]; CV [95%CI] = 1.7% [0.5–2.9]; MD95 = 9.2 Ns; MD90 = 7.7 Ns) demonstrated excellent intersession reliability. Most CMJ variables showed excellent reliability within sessions, while DJ had lower reliability in most metrics. These findings provide valuable information to physical trainers to select the metrics to assess athletes’ performance as well as to identify a minimum cut-off value that serves as a reference for each of the metrics reported in both tests.

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3