Influence of the Supply Voltage Variation on the Conducted Emission in the Frequency Range up to 150 kHz Injected into the Power Grid by CFL and LED Lamps—Case Study

Author:

Frydlewicz Wojciech1ORCID,Michalec Łukasz2ORCID,Kostyła Paweł2ORCID,Kaczorowska Dominika2ORCID,Sikorski Tomasz2ORCID

Affiliation:

1. Łukasiewicz Research Network—Institute of Electrical Engineering, 04-703 Warszawa, Poland

2. Faculty of Electrical Engineering, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland

Abstract

In normal operating conditions, the mains voltage level provided by low-voltage distribution networks follows time-varying patterns within permissible limits. The statistical characterisation of disturbances inserted into the power grid by nonlinear electrical devices is useful since operators are able to establish power quality limits and assess the residual capacity of networks for new smart installations, which may include a multitude of power electronic devices. Existing standards related to emission tests recommend using a power supply source in the measurement circuit with a nominal voltage parameter. However, the range of permissible variations of relevant supply voltage parameters may have an impact on conducted emissions. It can also be considered that the symptoms of supply voltage variations may manifest themselves differently depending on the equipment’s architecture and also the range of frequency observation with reference to harmonics and supraharmonics. The purpose of this study is to measure and analyze non-intentional conducted emissions injected into the power grid by lighting devices, methodically, by numbers of studies under different supply voltage conditions within two frequency bands. The emission is evaluated separately in two ranges: up to 2 kHz and 9-150 kHz. Obtained results show that the level of conducted emission introduced into the low voltage network by modern lighting sources like fluorescent and LED lamps varies with the supply voltage level compared to the emission generated in the nominal voltage level condition. Additionally, in the case of a spectrum of higher frequencies, some trends of shifting of the characteristic frequency bands are recorded. The potential of the obtained results is to complement the knowledge of the emission of modern lighting sources, which can be further used for digital models of these devices and to estimate the impact on the grid under real working conditions.

Funder

Faculty of Electrical Engineering of the Wroclaw University of Science and Technology

Publisher

MDPI AG

Reference57 articles.

1. Bollen, M., Rönnberg, S., Zavoda, F., Zhong, J., Djokic, S., Das, R., and Halpin, M. (2015, January 15–18). CIGRE/CIRED Working Group C4.24—Power Quality and EMC Issues Associated with Future Electricity Networks—Status Report. Proceedings of the 23rd International Conference on Electricity Distribution, Lyon, France.

2. Loads That Cause Power Quality Problems;Singh;Power Quality Problems and Mitigation Techniques,2015

3. Sahoo, S. (2020). Power Quality in Modern Power Systems, Academic Press.

4. Ojo, A., Awodele, K., and Sebitosi, A. (2019, January 3–17). Power Quality Monitoring and Assessment of a Typical Commercial Building. Proceedings of the IEEE AFRICON Conference, Moscow, Russia.

5. A Literature Survey on Power Quality Disturbances in the Frequency Range of 2–150 KHz;Subhani;Renew. Energy Power Qual. J.,2017