Abstract

High-voltage direct current (HVDC) transmission is preferred over high-voltage alternating current (HVAC) for long power lines for asynchronous power grid interconnection and high-level renewable energy integration. The control and protection functions associated with HVDC systems help with fast and secure clearance of faults. The control and protection challenges in the embedded HVDC network are of great concern for the stable and secure operation of an HVDC network. The DC fault current may reach an extremely high level in a rather short period because of the low impedance in a DC system, which is dangerous for converters, and disturbances in the AC network directly influence the performance of the HVDC system. Sometimes, faults on the AC side may lead to disconnection or failure of the DC link, causing reliability problems as well as huge economic losses. AC and DC protection solutions are being developed for HVDC systems to enhance their sustainability and reliability. As such, AC and DC faults should be detected and cleared at a faster rate. Therefore, in this article, the feasibility of the synchro-squeezed transform (SST) is analyzed for detection purposes. For more accurate and faster detection, the signal is first decomposed using the empirical mode decomposition (EMD) technique, and then the SST is applied. A discrete Teager energy (DTE) spectrum is obtained with the processed signal, which works as the detection index. The algorithm shows low sampling frequency requirements, with higher efficiency and reliability for the purpose. PSCAD/EMTDC version 4.6 software and MATLAB 2022a software is used for the modeling and simulation.

Funder

Østfold University College

Publisher

MDPI AG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3