Reproducibility of Mesopic and Photopic Pupil Sizes in Myopic Children Using a Dedicated Pupillometer with Human-Assisted or Automated Reading

Author:

Hvid-Hansen Anders1ORCID,Bækgaard Per2ORCID,Jacobsen Nina13,Hjortdal Jesper4,Møller Flemming5,Kessel Line13ORCID

Affiliation:

1. Department of Ophthalmology, Copenhagen University Hospital—Rigshospitalet-Glostrup, DK-2600 Glostrup, Denmark

2. Department of Applied Mathematics and Computer Science, Technical University of Denmark, DK-2800 Kongens Lyngby, Denmark

3. Department of Clinical Medicine, University of Copenhagen, DK-2200 København N, Denmark

4. Department of Ophthalmology, Aarhus University Hospital, DK-8200 Aarhus N, Denmark

5. Department of Ophthalmology, University Hospital of Southern Denmark—Vejle Hospital, DK-7100 Vejle, Denmark

Abstract

This study aimed to investigate the reproducibility of pupil size measurements over time and between reading methods when comparing human-assisted reading to automated reading. Pupillary data were analyzed on a subset of myopic children enrolled in a multicenter randomized clinical trial on myopia control with low-dose atropine. Pupil size measurements were obtained prior to randomization at two time points (screening and baseline visits) using a dedicated pupillometer under mesopic and photopic conditions. A customized algorithm was built to perform automated readings, allowing comparisons between human-assisted and automated readings. Reproducibility analyses followed the principles of Bland and Altman and included the calculation of the mean difference between measurements and limits of agreement (LOA). We included 43 children. Mean (standard deviation) age was 9.8 (1.7) years and 25 (58%) children were girls. Using human-assisted readings, reproducibility over time showed mesopic mean difference of 0.02 mm with LOA from −0.87 mm to 0.91 mm, whereas photopic mean difference was −0.01 mm with LOA from −0.25 mm to 0.23 mm. Reproducibility between human-assisted and automated readings was also higher under photopic conditions, with mean difference of 0.03 mm and LOA from −0.03 mm to 0.10 mm at screening and mean difference of 0.03 mm and LOA from −0.06 mm to 0.12 mm at baseline. Using a dedicated pupillometer, we found that examinations performed under photopic conditions demonstrated higher reproducibility over time and between reading methods. We speculate whether mesopic measurements are sufficiently reproducible to be monitored over time. Furthermore, photopic measurements may be of greater relevance when evaluating the side effects of atropine treatment, such as photophobia.

Funder

Bagenkop Nielsens Øjen-Fond

Fight for Sight Denmark

Fonden for Faglig Udvikling i Speciallægepraksis

The Danish Research Foundation

Synoptik-Fonden

Danish Regions

Gangstedfonden

Reimbursement from Regional COVID-19 funds

Aase og Ejnar Danielsens Fond

A.P. Møller Fonden

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3