Quantifying Left Atrial Size in the Context of Atrial Fibrillation Ablation: Which Echocardiographic Method Correlates to Outcome of Pulmonary Venous Isolation?

Author:

Leitz Patrick,Stebel Lena Marie,Andresen Christian,Ellermann ChristianORCID,Güner Fatih,Reinke Florian,Kochhäuser Simon,Frommeyer GerritORCID,Köbe Julia,Wasmer Kristina,Lange Philipp S.,Orwat StefanORCID,Eckardt Lars,Dechering Dirk G.

Abstract

Introduction: Multiple studies have shown that left atrial (LA) enlargement is a strong predictor of poor outcome after catheter ablation of atrial fibrillation (AF). LA size is commonly approximated as the diameter in the parasternal long axis. It remains unknown whether more precise echocardiographic measurements of LA size allow for better correlation with outcome after pulmonary vein isolation (PVI). Methods and results: We performed a retrospective study of 131 consecutive patients (43 females, 60% paroxysmal AF, mean CHA2DS2-Vasc score 1.6, mean age 61 ± 12 years) referred for PVI. Measurements of the LA were carried out by a single observer in transthoracic echocardiograms (TTE) performed prior to ablation. We calculated diameter of the LA in the parasternal long axis (PLAX), LA area in the 2- as well as 4-Chamber (CH) view. LA volume was computed using the disc summation technique (LAV) and indexed to body surface area (LAVI). Procedural and follow-up data were gathered from a prospective AF database. Ablation was performed exclusively using the second generation cryoballoon by the same operators. Follow-up visits at 3, 6 and 12 months showed freedom from AF in 76%, 73% and 73% respectively. Mean values of LA calculations were LAPLAX: 37.9 mm ± 6.3 mm, 2CH area: 22.5 cm2 ± 6.7 cm2, 4CH area: 21.4 cm2 ± 5.5 cm2, LAV: 73.7 mL ± 26.1 mL and LAVI: 36.2 mL/m2 ± 12.7 mL/m2, respectively. C statistic revealed the best concordance of LAVI with outcome after 12 months (C = 0.67), LAV also exhibited a satisfactory value (C = 0.61) in comparison to surfaces in 2CH (C = 0.59) and 4CH (C = 0.57). PLAX showed the worst correlation (C = 0.51). Additionally, different binary logistic regression models identified three independent predictors of AF outcome after cryoballoon PVI: gender (OR = 0.95 per year; p = 0.01); LAV (OR = 1.3/10mL; p = 0.02) and LAVI (OR = 1.58/10 mL/m2; p = 0.02). In all models, PLAX and area measurements were not predictive. Conclusions: Our data add further to evidence that LA size lends itself well as a predictor of PVI outcome. LAVI and LAV were independently predictive of rhythm outcome after PVI. This did not hold true for more commonly used measurements, such as PLAX diameter and surfaces of the LA, irrespective of the view chosen.

Publisher

MDPI AG

Subject

Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3