Water as a Source of Indoor Air Contamination with Potentially Pathogenic Aeromonas hydrophila in Aquaculture

Author:

Gołaś IwonaORCID,Szmyt MariuszORCID,Glińska-Lewczuk KatarzynaORCID

Abstract

Human activities influence the presence of potentially pathogenic bacteria in indoor air. The aim of this study was to determine the effect of the experimental rearing of European grayling and European perch in a recirculating aquaculture system on the contamination of indoor air with potentially pathogenic Aeromonas hydrophila (PPAH) and the resulting health risks to humans. The PPAH counts, their resistance to seven antibiotics, and the multiple antibiotic resistance (MAR) index were determined in samples of indoor air and water from rearing tanks. The PPAH counts were highest in the laboratory bioaerosol where two fish species were reared. The calculated indoor/outdoor ratio (I/O > 1) demonstrated that tank water was the internal source of PPAH emissions. The unconstrained PCA revealed strong positive relationships (p ≤ 0.05) between the PPAH counts in the indoor air and water samples. Most of the PPAH strains isolated from laboratory air were resistant to tetracycline, cefotaxime, and erythromycin, and 26–82% of the isolates exhibited multiple drug resistance. The values of the MAR index were similar in samples of laboratory air and water (0.23–0.34 and 0.24–0.36, respectively). Agglomerative clustering revealed two clusters of strains isolated from laboratory air and tank water. The results of this study indicate that aquaculture can be a source of indoor air contamination with PPAH.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Reference49 articles.

1. Plant/Soil Capacities to Remove Harmful Substances from Polluted Indoor Air. Plants and Environmental Quality Group, Centre for Ecotoxicology, UTS, Australiahttps://greenplantsforgreenbuildings.org/wpcontent/uploads/2014/01/HarmfulSubstancesPlantSoil.pdf

2. Phytoremediation of particulate matter from indoor air by Chlorophytum comosum L. plants

3. High bacterial load of indoor air in hospital wards: the case of University of Gondar teaching hospital, Northwest Ethiopia

4. Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3