A Study of the Plan and Performance Evaluation Method of an 8-m3 Chamber Using Ventilation Experiments and Numerical Analyses

Author:

Park SeonghyunORCID,Park Seongwoo,Seo Janghoo

Abstract

With increases in the time spent on indoor activities, the interests and technological demands regarding indoor air quality (IAQ) have also increased. Indoor air pollution is often caused by furniture or construction materials and chemical substances, such as volatile organic compounds (VOCs). As a way to remove such pollutants, efforts have been made to promote the management of indoor air quality through emission experiments. To conduct an experiment, such as the pollutant emission experiment involving substances harmful to the human body, a chamber to control various factors should be developed. By using such chambers, experimental variables can be minimized, quantitative analyses may be conducted, and the basic theory may be discussed. When the chamber is installed, it is not easy to change the existing installed conditions. Therefore, it is necessary to review feasibility with an accurate design. However, there is limited research on both how to quantitatively design the chamber and evaluate it. Therefore, this study investigates suitable chamber design methods and performance through ventilation performance evaluation to discuss potential development methods. In the chamber design step, a computational fluid dynamics (CFD) analysis was performed to estimate the ventilation efficiency according to the inlet and outlet positions to develop an 8-m3 chamber. Next, a ventilation experiment was performed using the tracer gas method for the performance evaluation, while the chamber interior airflow was simulated based on the CFD analysis. In a ventilation experiment using a tracer gas, the variation in gas density leads to concentration imbalance; as a result of concentration imbalance at each point, errors may occur in ventilation efficiency depending on the measurement point, causing the accuracy of the performance evaluation to fall. An attempt was made to resolve this problem by performing the ventilation experiment with a ceiling fan. The result indicated that the performance evaluation could be conducted without altering ventilation efficiency, coinciding with the CFD analysis result. Furthermore, when the concentration field was examined according to time in the CFD analysis, uniform concentration of chamber interior air allowed the ventilation efficiency to be calculated irrespective of the measurement point. Based on the findings, this study suggests a quantitative method of performance evaluation with an experiment in an 8-m3 chamber and a concurrent CFD analysis.

Funder

National Research Foundation of Korea

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3