(1) Background: In this study, two types of implants were compared—a conventional hip stem and a femoral neck prosthesis. (2) Methods: The femoral neck prosthesis study group included 21 patients, while the conventional hip stem control group was 40 patients. The first examination was the pre-op check, while the next ones were performed 6 weeks, 1 year, and 3 years after surgery. The Harris Hip Score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Hip Score (OHS), University of California at Los Angeles Activity Score (UCLA), and Visual Analog Scale EQ (VAS EQ) forms were completed at each clinical study visit. (3) Results: The HHS in the femoral neck prosthesis group and the conventional hip stem group 6 weeks after surgery was 68.8 ± 16.47 and 67.6 ± 8.92, respectively, and 1 year after surgery, this was 93 ± 5.58 vs. 90.6 ± 5.17, respectively. The OHS of the femoral neck prosthesis group was 34.8 points after 6 weeks, 45.5 points after 1 year, and 43.9 points after 3 years. The respective values in the conventional hip stem group were 35.5, 41.55, and 42.13 points. The WOMAC values for the femoral neck prosthesis group were 70.6, 92.7, and 86 points, respectively, while for the conventional hip stem group, they were 74, 88.1, and 86.1 points. The UCLA scores recorded in the conventional hip stem group ranged from 3.15 to 5.05 points, but a higher mean value of 5.33 points was obtained in the femoral neck prosthesis group. VAS EQ was equal to 84 points three years after the operation. (4) Conclusions: The study showed no significant differences in the functional scores of both groups, and the new type of cervical femoral stem could be the first choice in younger patients.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3