Author:
Banks David,Steven Jonathan,Black Adam,Naismith John
Abstract
A conceptual model is presented of two MW-scale low enthalpy mine water geothermal heat pump schemes that are being developed in Tyneside, UK. The Abbotsford Road scheme (54.955° N 1.556° W) is operating (as of May 2021) at 20–30 L/s, abstracting groundwater (and heat) from an unmined Coal Measures Upper Aquifer System (UAS) and reinjecting to the deeper High Main Aquifer System (HMAS), associated with the High Main (E) coal workings and the overlying High Main Post sandstone. A similar scheme, 700 m away at Nest Road (54.959° N 1.564° W), abstracts at 40 L/s from the HMAS, recovers heat from the mine water and reinjects the thermally spent water to deeper workings associated with the Hutton (L), Harvey-Beaumont (N) (and possibly other) coal seams, termed the Deep Mined Aquifer System (DMAS). The three aquifer systems are vertically discontinuous and possess different hydraulic (storage, transmissivity and continuity) properties that would have been near-impossible to predict in advance of drilling. At the sites, 10 boreholes were drilled to obtain five usable production/reinjection boreholes. Development of mine water geothermal energy schemes thus carries a significant project risk, and also a potential ongoing maintenance burden related to iron hydroxide scaling. These do not preclude mine water geothermal as a useful low carbon heating and cooling technology, but the involvement of skilled hydrogeologists, hydrochemists, mining and groundwater engineers is a pre-requisite.
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献